Viscoelastic properties of the human medial collateral ligament under longitudinal, transverse and shear loading

被引:131
作者
Bonifasi-Lista, C
Lake, SP
Small, MS
Weiss, JA
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Orthoped, Salt Lake City, UT 84132 USA
关键词
viscoelasticity; ligament; material properties; shear; MCL;
D O I
10.1016/j.orthres.2004.06.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ligament viscoelasticity controls viscous dissipation of energy and thus the potential for injury or catastrophic failure. Viscoelasticity under different loading conditions is likely related to the organization and anisotropy of the tissue. The objective of this study was to quantify the strain- and frequency-dependent viscoelastic behavior of the human medial collateral ligament (MCL) in tension along its longitudinal and transverse directions, and under shear along the fiber direction. The overall hypothesis was that human MCL would exhibit direction-dependent viscoelastic behavior, reflecting the composite structural organization of the tissue. Incremental stress relaxation testing was performed, followed by the application of small sinusoidal strain oscillations at three different equilibrium strain levels. The peak and equilibrium stress-strain curves for the longitudinal. transverse and shear tests demonstrate that the instantaneous and long-time stress-strain response of the tissue differs significantly between loading conditions of along-fiber stretch, cross-fiber stretch and along-fiber shear. The reduced relaxation curves demonstrated at least two relaxation times for all three test modes. Relaxation resulted in stresses that were 60-80% of the initial stress after 1000 s. Incremental stress relaxation proceeded faster at the lowest strain level for all three test configurations. Dynamic stiffness varied greatly with test mode and equilibrium strain level, and showed a modest but significant increase with frequency of applied strain oscillations for longitudinal and shear tests. Phase angle was unaffected by strain level (with exception of lowest strain level for longitudinal samples) but showed a significant increase with increasing strain oscillation frequency. There was no effect of test type on the phase angle. The increase in phase and thus energy dissipation at higher frequencies may protect the tissue from injury at faster loading rates. Results suggest that the long-time relaxation behavior and the short-time dynamic energy dissipation of ligament may be governed by different viscoelastic mechanisms, yet these mechanisms may affect tissue viscoelasticity similarly under different loading configurations. (C) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:67 / 76
页数:10
相关论文
共 46 条
[21]   THE EFFECT OF A LATHYRITIC DIET ON THE SENSITIVITY OF TENDON TO STRAIN RATE [J].
HAUT, RC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (02) :166-174
[22]   MECHANICAL RESPONSES OF TENDONS TO REPEATED EXTENSIONS AND WAIT PERIODS [J].
HUBBARD, RP ;
CHUN, KJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (01) :11-19
[23]   Strain in the medial collateral ligament of the human knee under single and combined loads [J].
Hull, ML ;
Berns, GS ;
Varma, H ;
Patterson, HA .
JOURNAL OF BIOMECHANICS, 1996, 29 (02) :199-206
[24]   Scanning electron microscopic characterization of healing and normal rat ligament microstructure under slack and loaded conditions [J].
Hurschler, C ;
Provenzano, PP ;
Vanderby, R .
CONNECTIVE TISSUE RESEARCH, 2003, 44 (02) :59-68
[25]   The viscoelastic behavior of the non-degenerate human lumbar nucleus pulposus in shear [J].
Iatridis, JC ;
Setton, LA ;
Weidenbaum, M ;
Mow, VC .
JOURNAL OF BIOMECHANICS, 1997, 30 (10) :1005-1013
[26]   ON THE VISCOELASTIC PROPERTIES OF THE ANTEROMEDIAL BUNDLE OF THE ANTERIOR CRUCIATE LIGAMENT [J].
KWAN, MK ;
LIN, THC ;
WOO, SLY .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :447-452
[27]   BAPN DOSE DEPENDENCE OF MATURE CROSS-LINKING IN BONE-MATRIX COLLAGEN OF RABBIT COMPACT-BONE - CORRESPONDING VARIATION OF SONIC VELOCITY AND EQUATORIAL DIFFRACTION SPACING [J].
LEES, S ;
EYRE, DR ;
BARNARD, SM .
CONNECTIVE TISSUE RESEARCH, 1990, 24 (02) :95-105
[28]  
Miyasaka K., 1991, AM J KNEE SURG, V4, P3
[29]   NONUNIFORM DISTRIBUTION OF COLLAGEN DENSITY IN HUMAN KNEE LIGAMENTS [J].
MOMMERSTEEG, TJA ;
BLANKEVOORT, L ;
KOOLOOS, JGM ;
HENDRIKS, JCM ;
KAUER, JMG ;
HUISKES, R .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) :238-245
[30]   BIPHASIC CREEP AND STRESS-RELAXATION OF ARTICULAR-CARTILAGE IN COMPRESSION - THEORY AND EXPERIMENTS [J].
MOW, VC ;
KUEI, SC ;
LAI, WM ;
ARMSTRONG, CG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01) :73-84