Toward metrological traceability for DNA fragment ratios in GM quantification. 1. Effect of DNA extraction methods on the quantitative determination of Bt176 corn by real-time PCR

被引:43
作者
Corbisier, Philippe
Broothaerts, Wim
Gioria, Sabrina
Schimmel, Heinz
Burns, Malcolm
Baoutina, Anna
Emslie, Kerry R.
Furui, Satoshi
Kurosawa, Yasunori
Holden, Marcia J.
Kim, Hyong-Ha
Lee, Yun-mi
Kawaharasaki, Mamoru
Sin, Della
Wang, Jing
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[2] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
[3] Natl Measurement Inst, Pymble, NSW 2073, Australia
[4] Natl Food Res Inst, GM Analyt Evaluat Team, Tsukuba, Ibaraki 3058642, Japan
[5] NIST, DNA Measurements Grp, Gaithersburg, MD 20899 USA
[6] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
[7] Natl Inst Adv Ind Sci & Technol, Inst Biol Resource & Funct, Tsukuba, Ibaraki 3058566, Japan
[8] Hong Kong Government Lab, Homantin Govt Off, Kowloon, Hong Kong, Peoples R China
[9] Natl Res Ctr Certified Reference Mat, Beijing 100013, Peoples R China
关键词
feed; food; genetically modified organism; GM; measurement uncertainty; extraction method; DNA; PCR;
D O I
10.1021/jf062931l
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
An international CCQM-P60 pilot study involving eight national metrological institutes was organized to investigate if the quantification of genetically modified (GM) corn powder by real-time PCR was affected by the DNA extraction method applied. Four commonly used extraction methods were compared for the extraction of DNA from a GM Bt176 corn powder. The CTAB-based method yielded the highest DNA template quantity and quality. A difference in the 260 nm/230 nm absorbance ratio was observed among the different extraction methods. Real-time amplification of sequences specific for endogenous genes zein and hmg as well as transgenic sequences within the cryIA(b) gene and a fragment covering the junction between the transformed DNA and the plant genome were used to determine the GM percentage. The detection of the transgenic gene was affected by the quantity and quality of template used for the PCR reaction. The Bt176 percentages measured on diluted or purified templates were statistically different depending on the extraction method applied.
引用
收藏
页码:3249 / 3257
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 215692005E ISO
[2]  
[Anonymous], 215712005E ISO
[3]  
[Anonymous], 2003, OFF J EUR UNION L, V268, P24
[4]  
*AUSTR NZ FOOD AUT, 2003, REV LAB GEN MOD GM F
[5]  
BICKLEY J, ANAL MOL BIOL QUALIT, P81
[6]   Critical points of DNA quantification by real-time PCR - effects of DNA extraction method and sample matrix on quantification of genetically modified organisms [J].
Cankar, Katarina ;
Stebih, Dejan ;
Dreo, Tanja ;
Zel, Jana ;
Gruden, Kristina .
BMC BIOTECHNOLOGY, 2006, 6 (1)
[7]   Quantitative determination of Roundup Ready soybean (Glycine max) extracted from highly processed flour [J].
Corbisier, P ;
Trapmann, S ;
Gancberg, D ;
Hannes, L ;
Van Iwaarden, P ;
Berben, G ;
Schimmel, H ;
Emons, H .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) :282-290
[8]   An inter-platform repeatability study investigating real-time amplification of plasmid DNA [J].
Donald, CE ;
Qureshi, F ;
Burns, MJ ;
Holden, MJ ;
Blasic, JR ;
Woolford, AJ .
BMC BIOTECHNOLOGY, 2005, 5 (1)
[9]  
*EN TS, 21568 EN TS
[10]  
GANGULI PK, 1970, REV CAN BIOL EXPTL, V29, P339