Pulsed flow chemistry: a new approach to solution handling for flow analysis coupled with chemiluminescence detection

被引:49
作者
Lewis, SW [1 ]
Francis, PS
Lim, KF
Jenkins, GE
Wang, XD
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Ctr Chiral & Mol Technol, Geelong, Vic 3217, Australia
[2] Precis Devices PL, Shoreham, Vic 3916, Australia
[3] Univ Cent Queensland, Sch Chem & Biomed Sci, Rockhampton, Qld 4702, Australia
关键词
D O I
10.1039/b005118g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel instrumentation for flow analysis, coupled with chemiluminescence detection, and based on pulsed flow chemistry is described. The pulsed flow chemistry manifold allows for rapid and efficient mixing of chemiluminescent reagent with sample immediately in front of the detector, thus giving high precision (less than 1% RSD) and detectability, particularly for rapid, short-lived emissions. The instrument is also characterised by a compact size, high sampling frequency (120-300 samples per hour) and low reagent consumption (less than 500 mu l per cycle). Other flow analysis modes (e.g., flow injection, continuous flow and stopped-flow) are available by simply altering software settings. The suitability of the system was shown by using chemiluminescence reactions of analytical significance, namely the oxidation of luminol with hexacyanoferrate(iii) in the presence of 4-hydroxy-3-methoxybenzeneacetic acid (homovanillic acid), and the reduction of acidic potassium permanganate by morphine in the presence of polyphosphates. The latter reaction was used to determine morphine in aqueous process samples and the results obtained with the pulsed flow instrument displayed good agreement (mean difference of 1.8%) with those of a previously validated flow injection analysis method.
引用
收藏
页码:1869 / 1874
页数:6
相关论文
共 29 条
[1]  
ABBOTT R W, 1986, Analytical Proceedings, V23, P25
[2]   DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1987, 112 (04) :397-406
[3]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[4]  
Ater JL, 1998, CANCER, V82, P1593, DOI 10.1002/(SICI)1097-0142(19980415)82:8<1593::AID-CNCR23>3.0.CO
[5]  
2-Z
[6]  
BAKER P, 1909, CHEM 2000, P27
[7]   DETERMINATION OF MORPHINE IN-PROCESS STREAMS USING FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
BARNETT, NW ;
ROLFE, DG ;
BOWSER, TA ;
PATON, TW .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :551-557
[8]   Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :131-139
[9]   Determination of α,4-dihydroxy-3-methoxybenzeneacetic acid (vanilmandelic acid) by flow injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection [J].
Barnett, NW ;
Francis, PS ;
Lewis, SW ;
Lim, KF .
ANALYTICAL COMMUNICATIONS, 1999, 36 (04) :131-134
[10]   Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :151-158