Photo-polymerization shrinkage-stress kinetics in resin-composites: methods development

被引:195
作者
Watts, DC
Marouf, AS
Al-Hindi, AM
机构
[1] Univ Manchester, Sch Dent, Manchester M15 6FH, Lancs, England
[2] Tishreen Univ, Sch Dent, Latakia, Syria
关键词
polymerisation shrinkage; stress; composite resin;
D O I
10.1016/S0109-5641(02)00123-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Studies of free shrinkage-strain kinetics on restoratives have begun to multiply. However, there have been fewer investigations of the more difficult problem of concurrent stress-kinetic measurements. The aim was to outline design parameters for a new methodology for this problem, amenable especially to light-cured materials, and to present illustrative results for a range of restorative composites. Methods. Absolute values of stress measurable for a given material and geometry are dependent upon the stiffness of the measurement system. In an infinitely stiff system, the measured stress would also tend towards infinity. Real teeth and their cavities are not infinitely stiff; they have elastic and visco-elastic compliance. Consequently, it is important that some minimal, but essentially constant compliance be allowed, whatever the final or time-dependent modulus of the material may be. This goal has been realised by measurement of the time-development, for a disk-geometry specimen (phi = 10, h approximate to 1.0 mm) of stress (S-r), with a calibrated cantilever beam-geometry load cell. A novel specimen-holder design was used for this purpose, held in a rigid base assembly. Specimen thicknesses (or gap-widths) of 0.8 and 1.2 mm were specifically investigated on four representative resin-composites. Concurrent measurements were made of the end-displacement of the cantilever load cell, relative to a lower glass plate retaining the specimen. Results. Load-calibration of the cantilever load cell gave an end-displacement per unit stress of circa 6 mum/MPa This compares with literature values for cuspal compliance or displacement of circa 20 mum. Re-normalisation of the stress-data was implemented. This was accomplished assuming Hooke's law behavior at each instant and equivalent to a stiffer system, with a correction (multiplier) factor of 4 on the raw-stress values. For the materials examined, resultant maximum-stress levels determined were circa 5-8 MPa Stress-levels obtained at 1.2 mm thickness were slightly higher (11-15%) than the level of stress obtained at 0.8 mm thickness. This is attributable to the greater mass of material undergoing shrinkage at 1.2 mm, offset slightly by the different C-factors. Significance. The new device is a practical and self-contained system for rapid and accurate measurement of stress-kinetics in photopolymerising and also self-cure materials. (C) 2002 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 46 条
[1]   Polymerization contraction stress in thin resin composite layers as a function of layer thickness [J].
Alster, D ;
Feilzer, AJ ;
de Gee, AJ ;
Davidson, CL .
DENTAL MATERIALS, 1997, 13 (03) :146-150
[2]   Effect of adhesive layer properties on stress distribution in composite restorations - a 3D finite element analysis [J].
Ausiello, P ;
Apicella, A ;
Davidson, CL .
DENTAL MATERIALS, 2002, 18 (04) :295-303
[3]  
BOUCHLICHER MR, 1997, AM J DENT, V10, P88
[4]  
Bouschlicher M R, 2000, J Esthet Dent, V12, P328, DOI 10.1111/j.1708-8240.2000.tb00242.x
[5]   ADHESIVE BONDING OF VARIOUS MATERIALS TO HARD TOOTH TISSUES - FORCES DEVELOPING IN COMPOSITE-MATERIALS DURING HARDENING [J].
BOWEN, RL ;
NEMOTO, K ;
RAPSON, JE .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1983, 106 (04) :475-477
[7]  
Carvalho RM, 1996, OPER DENT, V21, P17
[8]   THE DEFORMATION OF CUSPS BY BONDED POSTERIOR COMPOSITE RESTORATIONS - AN INVITRO STUDY [J].
CAUSTON, BE ;
MILLER, B ;
SEFTON, J .
BRITISH DENTAL JOURNAL, 1985, 159 (12) :397-400
[9]   Polymerization contraction stress in light-cured packable composite resins [J].
Chen, HY ;
Manhart, J ;
Hickel, R ;
Kunzelmann, KH .
DENTAL MATERIALS, 2001, 17 (03) :253-259
[10]   The effects of adhesive thickness on polymerization contraction stress of composite [J].
Choi, KK ;
Condon, JR ;
Ferracane, JL .
JOURNAL OF DENTAL RESEARCH, 2000, 79 (03) :812-817