Differences between locking loops and grasping loops: Effects on 2-strand core suture

被引:102
作者
Hotokezaka, S [1 ]
Manske, PR [1 ]
机构
[1] Washington Univ, Sch Med, Dept Orthoped Surg, St Louis, MO USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1997年 / 22A卷 / 06期
关键词
D O I
10.1016/S0363-5023(97)80038-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The differences between locking and grasping configurations used to suture lacerated flexor tendons were evaluated using a 2-strand core model in human cadaver tendon. Locking suture configurations tighten around bundles of tendon fibers with tension, while grasping loops do not tighten around but pull through tendon fibers and distract with tension. The greatest tensile strength was found in 1-locking, 2-locking, and 2-grasping suture loop configurations per suture strand. The 2-grasping loops per suture strand, however, had the great est distraction (gapping) as the suture material pulled through the tendon. A single locking configuration per strand yielded the maximum tensile strength with reduced distraction (gapping) at the repair site.
引用
收藏
页码:995 / 1003
页数:9
相关论文
共 20 条
[11]   CYCLIC STRESS-ANALYSIS OF FLEXOR TENDON REPAIR [J].
PRUITT, DL ;
MANSKE, PR ;
FINK, B .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (04) :701-707
[12]   A BIOMECHANICAL ANALYSIS OF A NEW INTERLOCK SUTURE TECHNIQUE FOR FLEXOR TENDON REPAIR [J].
ROBERTSON, GA ;
ALQATTAN, MM .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (01) :92-93
[13]   FLEXOR TENDON REPAIR USING A 6 STRAND METHOD OF REPAIR AND EARLY ACTIVE MOBILIZATION [J].
SAVAGE, R ;
RISITANO, G .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (04) :396-399
[14]   INVITRO STUDIES OF A NEW METHOD OF FLEXOR TENDON REPAIR [J].
SAVAGE, R .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (02) :135-141
[15]  
Strickland, 1995, J Am Acad Orthop Surg, V3, P44
[16]   AN EVALUATION OF SUTURE MATERIALS USED IN TENDON SURGERY [J].
TRAIL, IA ;
POWELL, ES ;
NOBLE, J .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (04) :422-427
[17]  
Urbaniak JR., 1975, AAOS S TENDON SURG H, P70
[18]  
VERDAN C, 1979, TENDON SURGERY HAND, P57
[19]   A BIOMECHANICAL COMPARISON OF TECHNIQUES OF FLEXOR TENDON REPAIR [J].
WAGNER, WF ;
CARROLL, C ;
STRICKLAND, JW ;
HECK, DA ;
TOOMBS, JP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (06) :979-983
[20]   OPTICAL HETERODYNE MEASUREMENT OF THE PHASE RETARDATION OF A QUARTER-WAVE PLATE [J].
YAO, L ;
ZHOU, ZY ;
WANG, RW .
OPTICS LETTERS, 1988, 13 (07) :553-555