Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating

被引:24
作者
Dai, YQ [1 ]
Shiu, KK [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
关键词
amperometric biosensor; glucose determination; copper undercoating; palladium deposition; poly(o-phenylenediamine) film;
D O I
10.1002/elan.200303037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive amperometric glucose biosensor based on immobilizing glucose oxidase in electropolymerized poly(o-phenylenediamine) film on glassy carbon electrode coated sequentially with copper and palladium layers has been developed. The steady-state amperometric response to glucose was determined by means of the oxidation of hydrogen peroxide generated by the enzymatic reaction at a potential of either + 0.70 or + 0.40 V (vs. Ag \ AgCl reference). The deposited copper/palladium layer showed great enhancement in the performance of the enzyme electrode, possibly due to its better electrocatalytic activity for hydrogen peroxide oxidation and large surface area. Effects of the relative loading of palladium, enzyme and polymer on the electrode performance were examined in detail. Sensitivity and detection limit for glucose determinations at + 0.70 V were about 7.3 muA/mM and 0.1 muM, respectively. A wide linear range up to 6.0 mM glucose could be achieved. Electrode performance was superior to similar works reported in the literature. The response time was less than 2 s and its lifetime was longer than three months. The permeable polyphenylenediamine film also offered good anti-interference ability to ascorbic acid, uric acid and acetaminophen, especially when a detection potential of + 0.40 V was employed.
引用
收藏
页码:1806 / 1813
页数:8
相关论文
共 32 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[2]   Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors [J].
Carelli, I ;
Chiarotto, I ;
Curulli, A ;
Palleschi, G .
ELECTROCHIMICA ACTA, 1996, 41 (11-12) :1793-1800
[3]   PERMEATION OF SOLUTES THROUGH AN ELECTROPOLYMERIZED ULTRATHIN POLY-O-PHENYLENEDIAMINE FILM USED AS AN ENZYME-ENTRAPPING MEMBRANE [J].
CENTONZE, D ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
ELECTROANALYSIS, 1994, 6 (5-6) :423-429
[4]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[5]  
Ekinci E, 1998, J APPL POLYM SCI, V68, P145, DOI 10.1002/(SICI)1097-4628(19980404)68:1<145::AID-APP16>3.0.CO
[6]  
2-#
[7]   ELECTROCHEMICAL PLATINIZATION OF RETICULATED VITREOUS CARBON ELECTRODES TO INCREASE BIOSENSOR RESPONSE [J].
HEIDER, GH ;
SASSO, SV ;
HUANG, KM ;
YACYNYCH, AM ;
WIECK, HJ .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1106-1110
[8]   Novel multifunctional polymers from aromatic diamines by oxidative polymerizations [J].
Li, XG ;
Huang, MR ;
Duan, W ;
Yang, YL .
CHEMICAL REVIEWS, 2002, 102 (09) :2925-3030
[9]   ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE [J].
LOBEL, E ;
RISHPON, J .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :51-53
[10]  
LOWENHEIM FA, 1978, ELECTROPLATING