A peptide-based fluorescent ratiometric sensor for quantitative detection of proteins

被引:26
作者
Choulier, Laurence [1 ]
Shvadchak, Volodymyr V. [2 ]
Naidoo, Aletia [1 ]
Klymchenko, Andrey S. [2 ]
Mely, Yves [2 ]
Altschuh, Daniele [1 ]
机构
[1] Univ Strasbourg, CNRS, Biosensor Grp, IREBS, F-67412 Illkirch Graffenstaden, France
[2] Univ Strasbourg, Fac Pharm, CNRS, UMR 7213,Lab Biophoton & Pharmacol, F-67401 Illkirch Graffenstaden, France
关键词
Detection; Fluorescence; Peptide biosensor; Quantification; Ratiometric dye; Surface plasmon resonance; BIOSENSOR TECHNOLOGY; DESIGN; CONSTRUCTION; ANTIBODIES; LIGANDS; BINDING; EPITOPE; DOMAIN;
D O I
10.1016/j.ab.2010.02.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A ratiometric fluorescent sensor was obtained by solid-phase synthesis of a peptide singly labeled at its N-terminus with a 3-hydroxychromone (3HC) derivative, an environmentally sensitive fluorophore with a two-band emission. The construct contains the binding site recognized by an antibody fragment, scFv1F4(Q34S), with nanomolar (nM) affinity. The dye only marginally affected the kinetic and equilibrium binding parameters of the scFv-peptide interaction, as measured by surface plasmon resonance. On interaction with the antibody fragment, the sensor showed up to 47% change in the ratio of its two emission bands, indicating an enhanced screening of the 3HC fluorophore from bulk water. Competition with two unlabeled peptides of different lengths led to a dynamic displacement of the construct governed by the relative binding constants. Calibration showed that the response is proportional to the ratio of scFv1F4(Q34S) to labeled peptide. The detection limit of scFv1F4(Q34S) was 15 nM. In a more complex medium (100 mu g/ml bovine serum albumin), the scFv could be detected in the 50- to 100-nM range. This work demonstrates that, with the perspective of further improvements of the dye spectroscopic properties, fluorescent ratiometric sensing based on small synthetic peptides represents a promising tool for quantitative target detection. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:188 / 195
页数:8
相关论文
共 32 条
[1]   Fluorescence sensing of intermolecular interactions and development of direct molecular biosensors [J].
Altschuh, Daniele ;
Oncul, Sule ;
Demchenko, Alexander P. .
JOURNAL OF MOLECULAR RECOGNITION, 2006, 19 (06) :459-477
[2]  
Ben Khalifa M, 2000, J MOL RECOGNIT, V13, P127
[3]   Local environment perturbations in alpha1-antitrypsin monitored by a ratiometric fluorescent label [J].
Boudier, Christian ;
Klymchenko, Andrey S. ;
Mely, Yves ;
Follenius-Wund, Anny .
PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2009, 8 (06) :814-821
[4]  
Chatellier J, 1996, J MOL RECOGNIT, V9, P39, DOI 10.1002/(SICI)1099-1352(199601)9:1<39::AID-JMR239>3.0.CO
[5]  
2-V
[6]   Computational design and biochemical characterization of maize nonspecific lipid transfer protein variants for biosensor applications [J].
Choi, Eun Jung ;
Mao, Jessica ;
Mayo, Stephen L. .
PROTEIN SCIENCE, 2007, 16 (04) :582-588
[7]   Kinetic analysis of the effect on fab binding of identical substitutions in a peptide and its parent protein [J].
Choulier, L ;
Rauffer-Bruyère, N ;
Ben Khalifa, M ;
Martin, F ;
Vernet, T ;
Altschuh, D .
BIOCHEMISTRY, 1999, 38 (12) :3530-3537
[8]   Comparative properties of two peptide-antibody interactions as deduced from epitope delineation [J].
Choulier, L ;
Orfanoudakis, G ;
Robinson, P ;
Laune, D ;
Ben Khalifa, M ;
Granier, C ;
Weiss, E ;
Altschuh, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 259 (1-2) :77-86
[9]   Delineation of a linear epitope by multiple peptide synthesis and phage display [J].
Choulier, L ;
Laune, D ;
Orfanoudakis, G ;
Wlad, H ;
Janson, JC ;
Granier, C ;
Altschuh, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 249 (1-2) :253-264
[10]   Theoretical analysis of protein concentration determination using biosensor technology under conditions of partial mass transport limitation [J].
Christensen, LLH .
ANALYTICAL BIOCHEMISTRY, 1997, 249 (02) :153-164