A peptide-based fluorescent ratiometric sensor for quantitative detection of proteins

被引:26
作者
Choulier, Laurence [1 ]
Shvadchak, Volodymyr V. [2 ]
Naidoo, Aletia [1 ]
Klymchenko, Andrey S. [2 ]
Mely, Yves [2 ]
Altschuh, Daniele [1 ]
机构
[1] Univ Strasbourg, CNRS, Biosensor Grp, IREBS, F-67412 Illkirch Graffenstaden, France
[2] Univ Strasbourg, Fac Pharm, CNRS, UMR 7213,Lab Biophoton & Pharmacol, F-67401 Illkirch Graffenstaden, France
关键词
Detection; Fluorescence; Peptide biosensor; Quantification; Ratiometric dye; Surface plasmon resonance; BIOSENSOR TECHNOLOGY; DESIGN; CONSTRUCTION; ANTIBODIES; LIGANDS; BINDING; EPITOPE; DOMAIN;
D O I
10.1016/j.ab.2010.02.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A ratiometric fluorescent sensor was obtained by solid-phase synthesis of a peptide singly labeled at its N-terminus with a 3-hydroxychromone (3HC) derivative, an environmentally sensitive fluorophore with a two-band emission. The construct contains the binding site recognized by an antibody fragment, scFv1F4(Q34S), with nanomolar (nM) affinity. The dye only marginally affected the kinetic and equilibrium binding parameters of the scFv-peptide interaction, as measured by surface plasmon resonance. On interaction with the antibody fragment, the sensor showed up to 47% change in the ratio of its two emission bands, indicating an enhanced screening of the 3HC fluorophore from bulk water. Competition with two unlabeled peptides of different lengths led to a dynamic displacement of the construct governed by the relative binding constants. Calibration showed that the response is proportional to the ratio of scFv1F4(Q34S) to labeled peptide. The detection limit of scFv1F4(Q34S) was 15 nM. In a more complex medium (100 mu g/ml bovine serum albumin), the scFv could be detected in the 50- to 100-nM range. This work demonstrates that, with the perspective of further improvements of the dye spectroscopic properties, fluorescent ratiometric sensing based on small synthetic peptides represents a promising tool for quantitative target detection. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:188 / 195
页数:8
相关论文
共 32 条
[11]   Construction of a fluorescent biosensor family [J].
De Lorimier, RM ;
Smith, JJ ;
Dwyer, MA ;
Looger, LL ;
Sali, KM ;
Paavola, CD ;
Rizk, SS ;
Sadigov, S ;
Conrad, DW ;
Loew, L ;
Hellinga, HW .
PROTEIN SCIENCE, 2002, 11 (11) :2655-2675
[12]   Monitoring Biophysical Properties of Lipid Membranes by Environment-Sensitive Fluorescent Probes [J].
Demchenko, Alexander P. ;
Mely, Yves ;
Duportail, Guy ;
Klymchenko, Andrey S. .
BIOPHYSICAL JOURNAL, 2009, 96 (09) :3461-3470
[14]   A peptide-based, ratiometric biosensor construct for direct fluorescence detection of a protein analyte [J].
Enander, Karin ;
Choulier, Laurence ;
Olsson, A. Linnea ;
Yushchenko, Dmytro A. ;
Kanmert, Daniel ;
Klymchenko, Andrey S. ;
Demchenko, Alexander P. ;
Mely, Yves ;
Altschuh, Daniele .
BIOCONJUGATE CHEMISTRY, 2008, 19 (09) :1864-1870
[15]  
Giovane C, 1999, J MOL RECOGNIT, V12, P141, DOI 10.1002/(SICI)1099-1352(199903/04)12:2<141::AID-JMR453>3.0.CO
[16]  
2-O
[17]   Protein engineering and the development of generic biosensors [J].
Hellinga, HW ;
Marvin, JS .
TRENDS IN BIOTECHNOLOGY, 1998, 16 (04) :183-189
[18]   VL position 34 is a key determinant for the engineering of stable antibodies with fast dissociation rates [J].
Hugo, N ;
Weidenhaupt, M ;
Beukes, M ;
Xu, B ;
Janson, JC ;
Vernet, T ;
Altschuh, D .
PROTEIN ENGINEERING, 2003, 16 (05) :381-386
[19]   Analyzing a kinetic titration series using affinity biosensors [J].
Karlsson, R ;
Katsamba, PS ;
Nordin, H ;
Pol, E ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2006, 349 (01) :136-147
[20]   Excited-state intramolecular proton transfer distinguishes microenvironments in single- and double-stranded DNA [J].
Klymchenko, Andrey S. ;
Shvadchak, Volodymyr V. ;
Yushchenko, Dmytro A. ;
Jain, Namrata ;
Mely, Yves .
JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (38) :12050-12055