First permanent implant of the Jarvik 2000 Heart

被引:92
作者
Westaby, S [1 ]
Banning, AP
Jarvik, R
Frazier, OH
Pigott, DW
Jin, XY
Catarino, PA
Saito, S
Robson, D
Freeland, A
Myers, TJ
Poole-Wilson, PA
机构
[1] John Radcliffe Hosp, Oxford Heart Ctr, Oxford OX3 9DU, England
[2] Texas Heart Inst, Houston, TX 77025 USA
[3] Jarvik Heart Inc, New York, NY USA
[4] Imperial Sch Med, Natl Heart & Lung Inst, London, England
[5] Royal Brompton Hosp, London SW3 6LY, England
关键词
D O I
10.1016/S0140-6736(00)02680-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Heart failure is a major public-health concern. Quality and duration of life on maximum medical therapy are poor. The availability of donor hearts is severely limited, therefore an alternative approach is necessary. We have explored the use of a new type of left-ventricular assist device intended as a long-term solution to end-stage heart failure. Methods As part of a prospective clinical trial, we implanted the first permanent Jarvik 2000 Heart-an intraventricular device with an innovative power delivery system-into a 61-year-old man (New York Heart Association functional class IV) with dilated cardiomyopathy. We assessed the effect of this left-ventricular assist device on both native heart function and the symptoms and systemic characteristics of heart failure. Findings The Jarvik 2000 Heart sustained the patient's circulation, and was practical and user-friendly. After 6 weeks, exercise tolerance, myocardial function, and endorgan function improved. Symptoms of heart failure have resolved, and continuous decreased pulse-pressure perfusion has had no adverse effects in the short term. There has been no significant haemolysis and no device-related complications. The skull-mounted pedestal is unobtrusive and has healed well. Conclusions The initial success of this procedure raises the possibility of a new treatment for end-stage heart failure. In the longer term, its role will be determined by mechanical reliability.
引用
收藏
页码:900 / 903
页数:4
相关论文
共 15 条
  • [1] CLINICAL USE OF THE TOTAL ARTIFICIAL-HEART
    DEVRIES, WC
    ANDERSON, JL
    JOYCE, LD
    ANDERSON, FL
    HAMMOND, EH
    JARVIK, RK
    KOLFF, WJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (05) : 273 - 278
  • [2] PREDICTING INTELLECTUAL LEVEL FROM THE MINI-MENTAL STATE EXAMINATION
    FARBER, JF
    SCHMITT, FA
    LOGUE, PE
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1988, 36 (06) : 509 - 510
  • [3] IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM
    FRAZIER, OH
    ROSE, EA
    MCCARTHY, P
    BURTON, NA
    TECTOR, A
    LEVIN, H
    KAYNE, HL
    POIRIER, VL
    DASSE, KA
    [J]. ANNALS OF SURGERY, 1995, 222 (03) : 327 - 338
  • [4] Improved left ventricular function after chronic left ventricular unloading
    Frazier, OH
    Benedict, CR
    Radovancevic, B
    Bick, RJ
    Capek, P
    Springer, WE
    Macris, MP
    Delgado, R
    Buja, LM
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (03) : 675 - 681
  • [5] Guyatt GH, 1993, J AM COLL CARDIOL S, V22, P185
  • [6] LVAD power delivery: A percutaneous approach to avoid infection
    Jarvik, R
    Westaby, S
    Katsumata, T
    Pigott, D
    Evans, RD
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (02) : 470 - 473
  • [7] KATSUMATA T, 1998, J CIRC SUPPORT, V1, P13
  • [8] REVERSAL OF CHRONIC VENTRICULAR DILATION IN PATIENTS WITH END-STAGE CARDIOMYOPATHY BY PROLONGED MECHANICAL UNLOADING
    LEVIN, HR
    OZ, MC
    CHEN, JM
    PACKER, M
    ROSE, EA
    BURKHOFF, D
    [J]. CIRCULATION, 1995, 91 (11) : 2717 - 2720
  • [9] Left ventricular assist devices and the failing heart - A bridge to recovery, a permanent assist device, or a bridge too far?
    Mann, DL
    Willerson, JT
    [J]. CIRCULATION, 1998, 98 (22) : 2367 - 2369
  • [10] Implantable LVAD infections: Implications for permanent use of the device
    McCarthy, PM
    Schmitt, SK
    Vargo, RL
    Gordon, S
    Keys, TF
    Hobbs, RE
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01) : 359 - 365