The use of toxic equivalency factor distributions in probabilistic risk assessments for dioxins, furans, and PCBs

被引:24
作者
Finley, BL
Connor, KT
Scott, PK
机构
[1] Exponent Inc, DABT, Santa Rosa, CA 95404 USA
[2] Exponent Inc, Natick, MA USA
[3] BB&L Sci, Pittsburgh, PA USA
来源
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES | 2003年 / 66卷 / 06期
关键词
D O I
10.1080/15287390306353
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Toxic equivalency factors (TEFs) for 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDFs) and coplanar polychlorinated biphenyl (PCB) congeners have been developed by the World Health Organization (WHO). Each TEF was derived from a range of relative potency (REP) estimates obtained from in vivo and in vitro studies wherein the potency of the congener was evaluated relative to 2,3,7,8-TCDD (or some other appropriate benchmark). For most congeners, the range of REP values spans several orders of magnitude, and the degree of conservatism varies widely among the congeners. Although some TEFs are greater than the maximum REP value, others are less than the minimum. This suggests that the point estimate TEFs introduce a significant amount of variability and uncertainty into the PCB and PCDD/F risk assessment process. The use of REP data distributions, rather than point estimate TEFs, would permit a more informed evaluation of the variability and uncertainty in the attendant risk estimates, Further, a standardized method of choosing a TEF from an REP distribution would ensure a uniform degree of conservatism in the TEF values. In this analysis, distributions of REP values were derived for the coplanar PCBs and 2,3,7,8-substituted PCDD/Fs. There are 936 REP values in the WHO database; the number of values per congener ranges from 7 (7,2,3,7,8,9-HxCDF) to 717 (PCB126). Twenty REP values qualified by WHO as "<" were replaced with one-half the stated value; 65 values qualified as ">" were not used, Fit tests indicate that most distributions are lognormal. Mean, standard deviation, and 50th and 95th percentile values for each REP distribution are presented. In general, the WHO TEFs for the PCDD/Fs are at the upper bound (75th percentile or greater) of the underlying REP distributions, while the PCB TEFs tend to be more representative of the central tendency of the underlying REP distribution, A simplistic weighting scheme that emphasizes long-term in vivo studies suggests that the REP distributions may not be overly sensitive to weighting techniques-that is, the statistical descriptors of the weighted distributions were similar to those of the unweighted distributions, A case study using fish tissue PCB and PCDD/F data suggests that in some settings the use of WHO TEFs may understate upper bound PCB risks relative to PCDD/F risks, A preliminary sensitivity analysis suggests that measurement endpoint, tissue-type and species (or strain) may be significant contributors to the variability and heterogeneity in the underlying REP data for some congeners, Although there are fundamental shortcomings inherent in any TEF scheme, evidence suggests that some form of REP distributions should be used in lieu of or in addition to point estimate TEFs in settings where PCBs and PCDD/Fs are commingled.
引用
收藏
页码:533 / 550
页数:18
相关论文
共 31 条
[1]
TOXIC EQUIVALENCY FACTORS FOR DIOXIN-LIKE PCBS - REPORT ON A WHO-ECEH AND IPCS CONSULTATION, DECEMBER 1993 [J].
AHLBORG, UG ;
BECKING, GC ;
BIRNBAUM, LS ;
BROUWER, A ;
DERKS, HJGM ;
FEELEY, M ;
GOLOR, G ;
HANBERG, A ;
LARSEN, JC ;
LIEM, AKD ;
SAFE, SH ;
SCHLATTER, C ;
WAERN, F ;
YOUNES, M ;
YRJANHEIKKI, E .
CHEMOSPHERE, 1994, 28 (06) :1049-1067
[2]
*AM IND HLTH COUNC, 1994, EXP FACT SOURC
[3]
[Anonymous], 2001, 540R02002 US EPA OFF
[4]
[Anonymous], INT PROC EST RISKS A
[5]
Disparity in quantitative risk assessment: A review of input distributions [J].
Binkowitz, BS ;
Wartenberg, D .
RISK ANALYSIS, 2001, 21 (01) :75-90
[6]
Use of toxic equivalency factors for risk assessment for dioxins and related compounds [J].
Birnbaum, LS ;
DeVito, MJ .
TOXICOLOGY, 1995, 105 (2-3) :391-401
[7]
Distributions of total job tenure for men and women in selected industries and occupations in the United States, February 1996 [J].
Burmaster, DE .
RISK ANALYSIS, 2000, 20 (02) :205-224
[8]
The dose-response model for dioxin [J].
Byrd, DM ;
Allen, DO ;
Beamer, RL ;
Besch, HR ;
Bylund, DB ;
Doull, J ;
Fleming, WW ;
Fries, A ;
Guengerich, FP ;
Hornbrook, R ;
Lasagna, L ;
Lum, BKB ;
Michaelis, EK ;
Morgan, ET ;
Poland, A ;
Rozman, KK ;
Smith, JB ;
Swanson, HI ;
Waddell, W ;
Wilson, JD .
RISK ANALYSIS, 1998, 18 (01) :1-2
[9]
RECOMMENDED DISTRIBUTIONS FOR EXPOSURE FACTORS FREQUENTLY USED IN HEALTH RISK ASSESSMENT [J].
FINLEY, B ;
PROCTOR, D ;
SCOTT, P ;
HARRINGTOIN, N ;
PAUSTENBACH, D ;
PRICE, P .
RISK ANALYSIS, 1994, 14 (04) :533-551
[10]
DEVELOPMENT OF A STANDARD SOIL-TO-SKIN ADHERENCE PROBABILITY DENSITY-FUNCTION FOR USE IN MONTE-CARLO ANALYSES OF DERMAL EXPOSURE [J].
FINLEY, BL ;
SCOTT, PK ;
MAYHALL, DA .
RISK ANALYSIS, 1994, 14 (04) :555-569