Latex-coated polymeric monolithic ion-exchange stationary phases. 2. Micro-ion chromatography

被引:105
作者
Zakaria, P
Hutchinson, JP
Avdalovic, N
Liu, Y
Haddad, PR
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[2] Dionex Chem Corp, Sunnyvale, CA 94088 USA
关键词
D O I
10.1021/ac048747l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Latex-coated monolithic polymeric stationary phases are used for micro-ion chromatography (mu-IC) of inorganic anions. Monolithic columns were prepared by the in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid within fused-silica capillaries of varying internal diameters. Introduction of ion-exchange sites was achieved by coating the anionic polymeric monolith with either Dionex AS10 or Dionex AS18 quaternary ammonium functionalized latex particles to give total ion-exchange capacities in the range 9-24 nequiv for a 30-cm column. The resultant mu-IC columns were used for the separation of anionic analytes using chloride or acetate as the eluent-competing ion and direct UV spectrophotometric detection at 195 nm or using hydroxide as the eluent-competing ion and suppressed or nonsuppressed contactless conductivity detection. Separation efficiencies of 13 000 plates/m were observed (for iodate), and separation efficiency was maintained for large increases in flow rate (up to 42 muL/min, corresponding to a linear flow velocity of 18.5 mm/s), enabling highly reproducible, rapid separations to be achieved (seven analyte anions in less than 2 min). Use of a hollow fiber micromembrane suppressor enabled effective suppression of hydroxide eluents over the range 0.5-5.0 mM, thereby permitting suppressed conductivity detection to be performed. However, the relatively large size of the suppressor resulted in reduced separation efficiencies (e.g., 5400 plates/m for iodate). Detection limits obtained with suppressed conductivity detection were in the range 0.4-1.2 muM.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 37 条
[1]   Capillary electrochromatography with monolithic silica column: I. Preparation of silica monoliths having surface-bound octadecyl moieties and their chromatographic characterization and applications to the separation of neutral and charged species [J].
Allen, D ;
El Rassi, Z .
ELECTROPHORESIS, 2003, 24 (03) :408-420
[2]  
Breadmore MC, 2002, ELECTROPHORESIS, V23, P3487, DOI 10.1002/1522-2683(200210)23:20<3487::AID-ELPS3487>3.0.CO
[3]  
2-5
[4]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[5]   Determination of the purity of phenoxymethylpenicillin by micellar electrokinetic chromatography and reversed phase liquid chromatography on a monolithic silica column [J].
Dolezalová, M ;
Cápová, H ;
Jobánek, R .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (08) :701-708
[6]   Characterization and modeling of monolithic stationary phases: application to preparative chromatography [J].
Ghose, S ;
Cramer, SM .
JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (01) :13-23
[7]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[8]  
Haddad P.R., 1990, ION CHROMATOGRAPHY P, DOI DOI 10.1016/S0301-4770(08)61141-0
[9]   Improved sensitivity and characterization of high-speed ion chromatography of inorganic anions [J].
Hatsis, P ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :995-1001
[10]   Ultra-fast HPLC separation of common anions using a monolithic stationary phase [J].
Hatsis, P ;
Lucy, CA .
ANALYST, 2002, 127 (04) :451-454