Evaluation of carbon paste electrodes modified with 1-furoylthioureas for the analysis of cadmium by differential pulse anodic stripping voltammetry

被引:23
作者
Estevez-Hernandez, O.
Naranjo-Rodriguez, I.
de Cisneros, J. L. Hidalgo-Hidalgo [1 ]
Reguera, E.
机构
[1] Univ La Habana, IMRE, Havana 10400, Cuba
[2] Univ Cadiz, Fac Ciencias, Dept Quim Analit, Cadiz, Spain
关键词
chemically modified carbon paste electrode; differential pulse anodic stripping voltammetry; cadmium(II); 1-furoylthioureas;
D O I
10.1016/j.snb.2006.09.030
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Two series of 1-furoylthioureas (FTHD) were used as modifiers of carbon paste electrodes (CPEs) for the analysis of Cd(II). The capacities of the newly FTHD-modified CPEs were calculated and the surface reactions during the preconcentration of Cd(H) were studied by cyclic voltammetry. The analyte was accumulated on the surface of the modified CPEs by complexing with FTHD 3,3-disubstituted (series 1) and 3-monosubstituted (series 2) and reduced at a negative potential (-1.0 V). It was then quantified by differential pulse anodic stripping voltammetry (DPASV) in Britton-Robinson buffer at pH 4. Experiments were conducted to establish the optimal carbon paste composition, electrolyte and pH of the determination, accumulation potential and time, and instrumental parameters. Under the optimized working conditions good linear correlations were obtained for the calibration graphs in the concentration ranges studied. For 5 min of accumulation time, detection limits using modified CPEs with ligands of series 2 were lower than that of series 1 (6 x 10(-5) mgL(-1) versus 3 x 10(-3) mgL-1, respectively, for the CPEs modified with 1-furoyl-3-p-tetradecylphenylthiourea and 1-furoyl-3-benzyl-3-phenylthiourea taken as models of both series). For a series of seven determinations of Cd(H) at 0.5 mg L-1 relative standard deviations below 3.9% were achieved for CPEs with ligands of both series. Only Pb(II) and Cu(II) apparently affected the electrochemical response of Cd(II). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:488 / 494
页数:7
相关论文
共 31 条
[1]
Bard A. J., 2001, ELECTROCHEMICAL METH, P44
[2]
Bond A.M., 1980, MODERN POLAROGRAPHIC
[3]
Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 464 (01) :99-114
[4]
Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode [J].
Bonfil, Y ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :285-296
[5]
Development and validation of a one-step immunoassay for determination of cadmium in human serum [J].
Darwish, IA ;
Blake, DA .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :52-58
[6]
DUNNICK JK, 1988, HDB TOXICITY INORGAN, pCH14
[7]
Simultaneous determination of trace amounts of cadmium, nickel and cobalt in water samples by adsorptive voltammetry using ammonium 2-amino-cyclopentene dithiocarboxylate as a chelating agent [J].
Ensafi, AA ;
Zarei, K .
TALANTA, 2000, 52 (03) :435-440
[8]
On the complex formation of CdCl2 with 1-furoylthioureas:: Preconcentration and voltammetric behavior of Cd(II) at carbon paste electrodes modified with 3-monosubstituted and 3,3-disubstituted derivatives [J].
Estevez-Hernadndez, O. ;
Hidalgo-Hidalgo de Cisneros, J. L. ;
Reguera, E. ;
Naranjo-Rodriguez, I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 120 (02) :766-772
[9]
Novel CdCl2 and HgCl2 complexes with 3-monosubstituted and 3,3-disubstituted 1-furoylthioureas:: IR and Raman spectra [J].
Estevez-Hernandez, O. ;
Otazo-Sanchez, E. ;
de Cisneros, J. L. Hidalgo-Hidalgo ;
Naranjo-Rodriguez, I. ;
Reguera, E. .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2006, 64 (04) :961-971
[10]
Fanta K, 2001, ELECTROANAL, V13, P484, DOI 10.1002/1521-4109(200104)13:6<484::AID-ELAN484>3.0.CO