QUANTIFICATION OF FLOW USING ULTRASOUND AND MICROBUBBLES: A DISRUPTION REPLENISHMENT MODEL BASED ON PHYSICAL PRINCIPLES

被引:88
作者
Hudson, John M. [1 ]
Karshafian, Raffi
Burns, Peter N.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
基金
加拿大健康研究院;
关键词
Contrast agents; Microbubble; Microcirculation; Blood flow; MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY; BLOOD-FLOW; INDUCED DESTRUCTION; ENHANCED US; PERFUSION; KINETICS; PHANTOM; AGENTS;
D O I
10.1016/j.ultrasmedbio.2009.06.1102
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Contrast-enhanced ultrasound (CEUS) is a promising clinical tool capable of noninvasively quantifying flow and relative vascular volume within the microcirculation. Quantification can be performed by recording the replenishment intensity time course of the imaging plane after the local disruption of agent during a constant infusion. Traditional analyses of the time-intensity curves have relied on mathematical functions (e. g., mono-exponential) that fail to consider the underlying physical principles of the flow system and the influence of the measurement device. In reality, the time-intensity curve reflects the hemodynamics and morphology of the vascular system being measured, the ultrasound field distribution and microbubble properties. We introduce a general analytic disruption replenishment model that attempts to account for these parameters and compare its performance to the established model in a flow phantom. Specifically, the proposed model incorporates the hemodynamic properties of the flow system (velocity distribution and vascular cross section); includes the elevation and axial plane pressure distributions; and accounts for the distinct high and low mechanical index (MI) disruption and detection boundaries. In addition, we demonstrated the importance of the ultrasound beam profile for accurate velocity quantification. It was shown that velocity estimates vary by up to 56% if the depth-dependent elevation thickness is not properly accounted for. Compared with the currently accepted mono-exponential model, the presented formalism was shown to be more robust in the presence of simulated motion artifacts and demonstrated better agreement in both the quality of the fit and estimation of velocity (similar to 3 to 10% vs. 90% error) for the same flow and acoustic conditions. (E-mail: hudsonjm@gmail.com) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2007 / 2020
页数:14
相关论文
共 28 条
[1]
[Anonymous], 2007, Foundations of Biomedical Ultrasound
[2]
A new formalism for the quantification of tissue perfusion by the destruct ion-replenishment method in contrast ultrasound Imaging [J].
Arditi, Marcel ;
Frinking, Peter J. A. ;
Zhou, Xiang ;
Rognin, Nicolas G. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (06) :1118-1129
[3]
ASSESSMENT OF MYOCARDIAL PERFUSION ABNORMALITIES WITH CONTRAST-ENHANCED TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
ARMSTRONG, WF ;
MUELLER, TM ;
KINNEY, EL ;
TICKNER, EG ;
DILLON, JC ;
FEIGENBAUM, H .
CIRCULATION, 1982, 66 (01) :166-173
[4]
An optimal lognormal approximation to lognormal sum distributions [J].
Beaulieu, NC ;
Xie, Q .
IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2004, 53 (02) :479-489
[5]
Correas Jean-Michel, 2006, Ultrasound Q, V22, P53
[6]
Crow EL., 1988, Lognormal distributions: theory and applications
[7]
INVIVO CORRELATION OF THERMODILUTION CARDIAC-OUTPUT AND VIDEODENSITOMETRIC INDICATOR-DILUTION CURVES OBTAINED FROM CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAMS [J].
DEMARIA, AN ;
BOMMER, W ;
KWAN, OL ;
RIGGS, K ;
SMITH, M ;
WATERS, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (04) :999-1004
[8]
The powerful microbubble: from bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond [J].
Feinstein, SB .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (02) :H450-H457
[9]
Contrast ultrasound imaging of the carotid artery vasa vasorum and atherosclerotic plaque neovascularization [J].
Feinstein, Steven B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :236-243
[10]
Attenuation and size distribution measurements of definity™ and manipulated definity™ populations [J].
Goertz, David E. ;
de Jong, Nico ;
van der Steen, Antonius F. W. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (09) :1376-1388