Attenuation and size distribution measurements of definity™ and manipulated definity™ populations

被引:224
作者
Goertz, David E.
de Jong, Nico
van der Steen, Antonius F. W.
机构
[1] Erasmus MC, Biomed Engn Thoraxctr, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Univ Twente, NL-7500 AE Enschede, Netherlands
关键词
contrast agents; microbubbles; intravascular ultrasound; vasa vasorum; mouse imaging; microcirculation; high frequency ultrasound;
D O I
10.1016/j.ultrasmedbio.2007.03.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The contrast agent Definity(TM) has recently been shown to have substantial nonlinear activity at high ultrasound frequencies (> 10 MHz). In this study, measurements were performed to characterize the frequency dependant attenuation properties of Definity(TM) and populations of DefinityTM that had been modified to preferentially isolate smaller bubbles through decantation or mechanical filtration. A narrowband pulse-echo substitution method was employed with a series of four transducers covering the frequency range from 2 to 50 MHz. '' Native '' Definity(TM) has peak in attenuation in the vicinity of 10 MHz and remains high until 50 MHz. This pattern is significantly different from other clinically approved agents and is consistent with recent reports of nonlinear activity at high frequencies. With increasing decantation times, the attenuation peak becomes more diffuse and occurs at progressively higher frequencies. By 3 h for example, attenuation continues to rise until 30 MHz. The bubble size distribution undergoes preferential skewing toward smaller bubbles with increasing decantation time. Between 30 s and 3 h, the mean bubble diameter goes from 3.99 to 0.98 micrometers. Mechanical filtration with 2 and 1 mu m pores causes attenuation to rise until 15 and 40 MHz, respectively. Definity(TM) can therefore be manipulated to improve its relative activity at higher frequencies (> 10 MHz), which has implications for ultrasound biomicroscopy and intravascular ultrasound applications. Further, these results suggest that agent handling can have a substantial impact on size distributions affecting lower frequency applications. Shell friction estimates derived from these data are lower than those reported for larger bubbles at lower frequencies. (E-mail: goertz@sri.sunnybrook.utoronto.ca) (c) 2007 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1376 / 1388
页数:13
相关论文
共 45 条
[1]   Dissolution behavior of lipid monolayer-coated, air-filled microbubbles: Effect of lipid hydrophobic chain length [J].
Borden, MA ;
Longo, ML .
LANGMUIR, 2002, 18 (24) :9225-9233
[2]   On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent [J].
Bouakaz, A ;
de Jong, N ;
Cachard, C ;
Jouini, K .
ULTRASONICS, 1998, 36 (1-5) :703-708
[3]   Ultrasound contrast agent in intravascular echography: An in vitro study [J].
Cachard, C ;
Finet, G ;
Bouakaz, A ;
Tabib, A ;
Francon, D ;
Gimenez, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :705-717
[4]   On the suitability of broadband attenuation measurement for characterizing contrast microbubbles [J].
Chatterjee, D ;
Sarkar, K ;
Jain, P ;
Schreppler, NE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06) :781-786
[5]   A Newtonian rheological model for the interface of microbubble contrast agents [J].
Chatterjee, D ;
Sarkar, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12) :1749-1757
[6]   Ultrasound attenuation in encapsulated microbubble suspensions: The multiple scattering effects [J].
Chen, Jiusheng ;
Zhu, Zhemin .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06) :961-969
[7]   Pressure-dependent attenuation in ultrasound contrast agents [J].
Chen, Q ;
Zagzebski, J ;
Wilson, T ;
Stiles, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (08) :1041-1051
[8]  
Cheung K, 2005, ULTRASON, P850
[9]   Brandaris 128:: A digital 25 million frames per second camera with 128 highly sensitive frames [J].
Chin, CT ;
Lancée, C ;
Borsboom, J ;
Mastik, F ;
Frijlink, ME ;
de Jong, N ;
Versluis, M ;
Lohse, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (12) :5026-5034
[10]   THE EFFECTS OF AN ELASTIC SOLID-SURFACE LAYER ON THE RADIAL PULSATIONS OF GAS-BUBBLES [J].
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1510-1521