Principles of PET/CT and clinical application

被引:6
作者
Bockisch, A
Beyer, T
Antoch, G
Veit, R
Müller, S
Pink, R
Rosenbaum, S
Kühl, H
机构
[1] Univ Essen Gesamthsch, Klin Nuklearmed, D-45122 Essen, Germany
[2] Univ Essen Gesamthsch, Inst Diagnost & Intervent Radiol, D-45122 Essen, Germany
来源
RADIOLOGE | 2004年 / 44卷 / 11期
关键词
PET/CT; PET; CT; image fusion; coregistration;
D O I
10.1007/s00117-004-1122-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Medicine today imposes high demands on diagnosing disease. Techniques should be preferably noninvasive, identify the disease at an early stage, and be quick and accurate. Frequently, these demands can only be met by employing various diagnostic modalities. Consequently, the integration of two imaging modalities, such as the combination of PET and CT, increases the quality of coregistration and facilitates a timely diagnosis. However, complex imaging procedures require a judicious choice of the areas of application. If, for example, both PET and CT are indicated then a combined PET/CT exam results in improved diagnosis, whereby the actual benefit will depend upon the clinical problem. Typically we expect an advantage of 10% with PET/CT compared to separate examinations with CT and PET In addition, PET/CT allows for new indications and applications, which cannot be performed satisfactorily with independent examinations and retrospective image alignment. One example is the application of PET/CT in radiation therapy planning.
引用
收藏
页码:1045 / +
页数:9
相关论文
共 25 条
[1]  
Aigner RM, 2003, NUKLEARMED-NUCL MED, V42, P210
[2]   Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology [J].
Antoch, G ;
Vogt, FM ;
Freudenberg, LS ;
Nazaradeh, F ;
Goehde, SC ;
Barkhausen, J ;
Dahmen, G ;
Bockisch, A ;
Debatin, JF ;
Ruehm, SG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (24) :3199-3206
[3]  
Antoch G, 2004, J NUCL MED, V45, p56S
[4]  
Antoch G, 2002, J NUCL MED, V43, P1339
[5]  
Bar-Shalom R, 2003, J NUCL MED, V44, P1200
[6]  
Beyer T, 2004, J NUCL MED, V45, p25S
[7]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[8]   Positron emission tomography/computed tomography-imaging protocols, artifacts, and pitfalls [J].
Bockisch, A ;
Beyer, T ;
Antoch, G ;
Freudenberg, LS ;
Kühl, H ;
Debatin, JF ;
Müller, SP .
MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (04) :188-199
[9]  
Cremerius U, 2003, NUKLEARMED-NUCL MED, V42, P234
[10]  
FREUDENBERG L, 2003, STRAHLENSCHUTZ BEI M, pS60