Experimental assessment of stress patterns in abdominal aortic aneurysms using the photoelastic method

被引:33
作者
Morris, L [1 ]
O'Donnell, P
Delassus, P
McGloughlin, T
机构
[1] Univ Limerick, Biomed Engn Res Ctr, Dept Mech & Aeronaut Engn, Limerick, Ireland
[2] Galway & Mayo Inst Technol, Dept Mech & Ind Engn, Galway, Ireland
关键词
abdominal aortic aneurysm; maximum sac diameter; reflective photoelastic method; rupture sites; self-supporting structure;
D O I
10.1111/j.1475-1305.2004.00157.x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Abdominal aortic aneurysm (AAA) sac size is a major clinical problem. The maximum sac diameter is the major determining factor for treatment. There is a direct correlation between the wall stress and rupture sites for AAA with maximum wall stress not being dependent on the maximum diameter of the vessel but on the morphology of vessel. The reflective photoelastic method was developed to experimentally evaluate the stresses and strains in a model AAA. The epoxy resin material was used as the self-supporting structure and had similar mechanical properties to the aneurysmal aorta. For both static and dynamic fluid testing the high-stressed regions were located proximally and distally to he aneurysm. This correlates to reported in vivo rupture sites. There was a low-stress region at the location of greatest diameter at the centre of the aneurysm. The direction of the maximum principal stress was found to be in the circumferential direction. The maximum stress for a high blood pressure of 22.7 kPa (170 mmHg) was 35% greater than that for a normal blood pressure of 16.0 kPa (120 mmHg). The photoelastic method is a powerful and innovative method of analysing stresses in AAA models, producing results, which are visual and easy to interpret.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 32 条
[1]  
Brown SK, 1996, FRUIT BREEDING, V1, P213
[2]   Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm [J].
Di Martino, ES ;
Guadagni, G ;
Fumero, A ;
Ballerini, G ;
Spirito, R ;
Biglioli, P ;
Redaelli, A .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) :647-655
[3]   STEADY FLOW THROUGH COLLAPSIBLE TUBES - MEASUREMENTS OF FLOW AND GEOMETRY [J].
ELAD, D ;
SAHAR, M ;
AVIDOR, JM ;
EINAV, S .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (01) :84-91
[4]   Reflection photoelasticity: a new method for studies of clinical mechanics in prosthetic dentistry [J].
Fernandes, CP ;
Glantz, POJ ;
Svensson, SA ;
Bergmark, A .
DENTAL MATERIALS, 2003, 19 (02) :106-117
[5]   Prediction of rupture risk in abdominal aortic aneurysm during observation: Wall stress versus diameter [J].
Fillinger, MF ;
Marra, SP ;
Raghavan, ML ;
Kennedy, FE .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) :724-732
[6]   In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk [J].
Fillinger, MF ;
Raghavan, ML ;
Marra, SP ;
Cronenwett, JL ;
Kennedy, FE .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) :589-597
[7]   Should endovascular surgery lower the threshold for repair of abdominal aortic aneurysms? [J].
Finlayson, SRG ;
Birkmeyer, JD ;
Fillinger, MF ;
Cronenwett, JL .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (06) :973-984
[8]   A CRITICAL-REVIEW OF THE BIOMECHANICAL STRESS-ANALYSIS OF THE HUMAN FEMUR [J].
GDOUTOS, EE ;
RAFTOPOULOS, DD ;
BARIL, JD .
BIOMATERIALS, 1982, 3 (01) :2-8
[9]   Integration of plantar soft tissue stiffness measurements in routine MRI of the diabetic foot [J].
Gefen, A ;
Megido-Ravid, M ;
Azariah, M ;
Itzchak, Y ;
Arcan, M .
CLINICAL BIOMECHANICS, 2001, 16 (10) :921-925
[10]   BIOMECHANICAL STUDY OF CONSTITUTIVE LAWS OF VASCULAR WALLS [J].
HAYASHI, K ;
SATO, M ;
HANDA, H ;
MORITAKE, K .
EXPERIMENTAL MECHANICS, 1974, 14 (11) :440-444