Recent developments and applications of chemiluminescence sensors

被引:51
作者
Aboul-Enein, HY
Stefan, RI
van Staden, JF
Zhang, XR
Garcia-Campana, AM
Baeyens, WRG
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmaceut Anal Lab, Riyadh 11211, Saudi Arabia
[2] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
[3] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[4] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
[5] Univ Ghent, Fac Pharmaceut Sci, Dept Pharmaceut Anal, B-9000 Ghent, Belgium
关键词
chemiluminescence sensors; immunosensors; microbial sensors; flow injection analysis applications;
D O I
10.1080/10408340008984161
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemiluminescence sensors are important tools in analytical chemistry due to their high sensitivity selectivity. This review presents the instrumentation involved in their design, including light detection and flow injection analysis system used. Various applications for the analysis of inorganic and organic compounds from gaseous samples and solutions indicate that these sensors are used with good reproducibility and selectivity of the analytes at low concentration level.
引用
收藏
页码:271 / 289
页数:19
相关论文
共 73 条
[1]   Genetically engineered molecular networks for biosensing systems [J].
Aizawa, M ;
Yanagida, Y ;
Haruyama, T ;
Kobatake, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) :204-211
[2]  
[Anonymous], 1984, PRACTICAL ABSORPTION
[3]   GAS-SENSING INTERNAL ENZYME FIBER OPTIC BIOSENSOR FOR HYDROGEN-PEROXIDE [J].
ARNOLD, MA ;
ZHOU, XG ;
PETSCH, RS .
TALANTA, 1994, 41 (05) :783-787
[4]   Chemiluminescence-based detection:: principles and analytical applications in flowing streams and in immunoassays [J].
Baeyens, WRG ;
Schulman, SG ;
Calokerinos, AC ;
Zhao, Y ;
Campaña, AMG ;
Nakashima, K ;
De Keukeleire, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :941-953
[5]   Selectivity comparison of neutral carrier-based ion-selective optical and potentiometric sensing schemes [J].
Bakker, E .
ANALYTICA CHIMICA ACTA, 1997, 350 (03) :329-340
[6]  
BANSHO K, 1993, BUNSEKI KAGAKU, V42, P55
[7]   MULTICOMPONENT ORGANIZED BIOACTIVE LAYERS FOR FIBEROPTIC LUMINESCENT SENSORS [J].
BLUM, LJ ;
GAUTIER, SM ;
BERGER, A ;
MICHEL, PE ;
COULET, PR .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) :1-9
[8]   MONITORING GLUTAMINE IN ANIMAL-CELL CULTURES USING A CHEMILUMINESCENCE FIBER OPTIC BIOSENSOR [J].
CATTANEO, MV ;
LUONG, JHT .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (06) :659-665
[9]   CHEMILUMINESCENT CHEMICAL SENSORS FOR OXYGEN AND NITROGEN-DIOXIDE [J].
COLLINS, GE ;
ROSEPEHRSSON, SL .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2224-2230
[10]   Gas-phase chemical sensing using electrochemiluminescence [J].
Collins, GE .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :202-206