Selective motor unit recruitment via intrafascicular multielectrode stimulation

被引:42
作者
McDonnall, D [1 ]
Clark, GA [1 ]
Normann, RA [1 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
关键词
functional neuromuscular stimulation (FNS); microelectrode array; neuroprosthesis; intrafascicular multielectrode stimulation (IFMS);
D O I
10.1139/Y04-047
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Recruitment of force via independent asynchronous firing of large numbers of motor units produces the grace and endurance of physiological motion. We have investigated the possibility of reproducing this physiological recruitment strategy by determining the selectivity of access to large numbers of independent motor units through intrafascicular multielectrode stimulation (IFMS) of the peripheral nerve. A Utah Slanted Electrode Array containing 100, 0.5-1.5 mm-long penetrating electrodes was inserted into the sciatic nerve of a cat, and forces generated by the 3 heads of triceps surea in response to electrical stimulation of the nerve were monitored via force transducers attached to their tendons. We found a mean of 17.4 +/- 4.9 (mean +/- SEM) electrodes selectively excited maximal forces in medial gastrocnemius before exciting another muscle. Among electrodes demonstrating selectivity at threshold, a mean of 7.3 +/- 2.7 electrodes were shown to recruit independent populations of motor units innervating medial gastrocnemius (overlap < 20%). Corresponding numbers of electrodes were reported for lateral gastrocnemius and soleus, as well. We used these stimulation data to emulate physiological recruitment strategies, and found that independent motor unit pool recruitment approximates physiological activation more closely than does intensity-based recruitment or frequency-based recruitment.
引用
收藏
页码:599 / 609
页数:11
相关论文
共 32 条
[1]  
[Anonymous], NEURAL PROSTHESES RE
[2]   Peripheral nerve stimulation for restoration of motor function [J].
Bhadra, N ;
Peckham, PH .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1997, 14 (05) :378-393
[3]   A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats [J].
Branner, A ;
Normann, RA .
BRAIN RESEARCH BULLETIN, 2000, 51 (04) :293-306
[4]   Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes [J].
Branner, A ;
Stein, RB ;
Normann, RA .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 85 (04) :1585-1594
[5]   PHYSIOLOGICAL TYPES AND HISTOCHEMICAL PROFILES IN MOTOR UNITS OF CAT GASTROCNEMIUS [J].
BURKE, RE ;
LEVINE, DN ;
TSAIRIS, P ;
ZAJAC, FE .
JOURNAL OF PHYSIOLOGY-LONDON, 1973, 234 (03) :723-+
[6]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[7]   ROBUST CLOSED-LOOP CONTROL OF ISOMETRIC MUSCLE FORCE USING PULSEWIDTH MODULATION [J].
CHIZECK, HJ ;
CRAGO, PE ;
KOFMAN, LS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (07) :510-517
[8]  
Crago PE, 1996, J REHABIL RES DEV, V33, P158
[9]   CLOSED-LOOP CONTROL OF FORCE DURING ELECTRICAL-STIMULATION OF MUSCLE [J].
CRAGO, PE ;
MORTIMER, JT ;
PECKHAM, PH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (06) :306-311
[10]  
CRAGO PE, 1981, P 4 ANN C REH ENG, P206