Development of miniature all-solid-state potentiometric sensing system

被引:83
作者
Anastasova-Ivanova, Salzitsa [1 ]
Mattinen, Ulriika [2 ,3 ]
Radu, Aleksandar [1 ]
Bobacka, Johan [2 ,3 ]
Lewenstam, Andrzej [2 ,3 ]
Migdalski, Jan [4 ]
Danielewskic, Marek [4 ]
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Adapt Sensors Grp, Dublin 9, Ireland
[2] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, FI-20500 Turku, Finland
[3] Abo Akad Univ, Ctr Proc Analyt Chem & Sensor Technol ProSens, FI-20500 Turku, Finland
[4] AGH Univ Sci & Technol, PL-30059 Krakow, Poland
基金
爱尔兰科学基金会;
关键词
Solid-contact electrode; Ion-selective electrode; Reference electrode; Potentiometry; Speciation; Water analysis; ION-SELECTIVE ELECTRODES; POLYMERIC MEMBRANE ELECTRODES; CONDUCTING POLYMERS; AQUEOUS-SOLUTIONS; CONTACT; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); TRANSDUCERS; STABILITY; BEHAVIOR; SENSORS;
D O I
10.1016/j.snb.2010.02.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the development of a pen-like, multi-electrode potentiometric sensing platform is described. The platform comprises a seven-in-one electrode incorporating all-solid-state ion-selective and reference electrodes based on the conductive polymer (poly(3,4-ethylenedioxythiophene)(PEDOT)) as an intermediate layer between the contacts and ion-selective membranes. The ion-selective electrodes are based on traditional, ionophore-based membranes, while the reference electrode is based on a polymer membrane doped with the lipophilic salt tetrabutyl ammonium tetrabutyl borate (TBA-TBB). The electrodes, controlled with a multichannel detector system, were used for simultaneous determination of the concentration of Pb2+ and pH in environmental water samples. The results obtained using pH-selective electrodes were compared with data obtained using a conventional pH meter and the average percent difference was 0.3%. Furthermore, the sensing system was successfully used for lead-speciation analysis in environmental water samples. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 38 条
[1]   OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES [J].
BAKKER, E ;
XU, AP ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :253-262
[2]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix [J].
Blaz, T ;
Migdalski, J ;
Lewenstam, A .
ANALYST, 2005, 130 (05) :637-643
[5]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[6]   Conducting polymer-based solid-state ion-selective electrodes [J].
Bobacka, J .
ELECTROANALYSIS, 2006, 18 (01) :7-18
[7]   COATED WIRE ION SELECTIVE ELECTRODES [J].
CATTRALL, RW ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1905-&
[8]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[9]   A photo-cured calcium ion-selective electrode for use in flow injection potentiometry that tolerates high perchlorate levels [J].
Dimitrakopoulos, T ;
Farrell, JR ;
Iles, PJ .
ELECTROANALYSIS, 1996, 8 (04) :391-395
[10]  
Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO