Development of miniature all-solid-state potentiometric sensing system

被引:83
作者
Anastasova-Ivanova, Salzitsa [1 ]
Mattinen, Ulriika [2 ,3 ]
Radu, Aleksandar [1 ]
Bobacka, Johan [2 ,3 ]
Lewenstam, Andrzej [2 ,3 ]
Migdalski, Jan [4 ]
Danielewskic, Marek [4 ]
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Adapt Sensors Grp, Dublin 9, Ireland
[2] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, FI-20500 Turku, Finland
[3] Abo Akad Univ, Ctr Proc Analyt Chem & Sensor Technol ProSens, FI-20500 Turku, Finland
[4] AGH Univ Sci & Technol, PL-30059 Krakow, Poland
基金
爱尔兰科学基金会;
关键词
Solid-contact electrode; Ion-selective electrode; Reference electrode; Potentiometry; Speciation; Water analysis; ION-SELECTIVE ELECTRODES; POLYMERIC MEMBRANE ELECTRODES; CONDUCTING POLYMERS; AQUEOUS-SOLUTIONS; CONTACT; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); TRANSDUCERS; STABILITY; BEHAVIOR; SENSORS;
D O I
10.1016/j.snb.2010.02.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the development of a pen-like, multi-electrode potentiometric sensing platform is described. The platform comprises a seven-in-one electrode incorporating all-solid-state ion-selective and reference electrodes based on the conductive polymer (poly(3,4-ethylenedioxythiophene)(PEDOT)) as an intermediate layer between the contacts and ion-selective membranes. The ion-selective electrodes are based on traditional, ionophore-based membranes, while the reference electrode is based on a polymer membrane doped with the lipophilic salt tetrabutyl ammonium tetrabutyl borate (TBA-TBB). The electrodes, controlled with a multichannel detector system, were used for simultaneous determination of the concentration of Pb2+ and pH in environmental water samples. The results obtained using pH-selective electrodes were compared with data obtained using a conventional pH meter and the average percent difference was 0.3%. Furthermore, the sensing system was successfully used for lead-speciation analysis in environmental water samples. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 38 条
[21]   Solid-Contact Reference Electrodes Based on Lipophilic Salts [J].
Mattinen, Ulriika ;
Bobacka, Johan ;
Lewenstam, Andrzej .
ELECTROANALYSIS, 2009, 21 (17-18) :1955-1960
[22]   Polyion sensors as liquid junction-free reference electrodes [J].
Mi, YM ;
Mathison, S ;
Bakker, E .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (04) :198-200
[23]   All-solid-state calcium solvent polymeric membrane electrode for low-level concentration measurements [J].
Michalska, A ;
Konopka, A ;
Maj-Zurawska, M .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :141-144
[24]  
NAGY K, 1997, J ELECTROCHEM SOC, V144, P1
[25]   Potentiometric sensor for the measurement of Cd2+ transport in yeast and plants [J].
Plaza, S ;
Szigeti, Z ;
Geisler, M ;
Martinoia, E ;
Aeschlimann, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) :10-16
[26]  
Püntener M, 2002, ELECTROANAL, V14, P1329, DOI 10.1002/1521-4109(200211)14:19/20<1329::AID-ELAN1329>3.0.CO
[27]  
2-V
[28]   Guidelines for improving the lower detection limit of ion-selective electrodes: A systematic approach [J].
Radu, Aleksandar ;
Peper, Shane ;
Bakker, Eric ;
Diamond, Dermot .
ELECTROANALYSIS, 2007, 19 (2-3) :144-154
[29]   Trace-level determination of Cs+ using membrane-based ion-selective electrodes [J].
Radu, Aleksandar ;
Peper, Shane ;
Gonczy, Chad ;
Runde, Wolfgang ;
Diamond, Dermot .
ELECTROANALYSIS, 2006, 18 (13-14) :1379-1388
[30]   Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes [J].
Schnierle, P ;
Kappes, T ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 1998, 70 (17) :3585-3589