Application of tandem mass spectrometry combined with gas chromatography and headspace solid-phase dynamic extraction for the determination of drugs of abuse in hair samples

被引:55
作者
Lachenmeier, DW [1 ]
Kroener, L [1 ]
Musshoff, F [1 ]
Madea, B [1 ]
机构
[1] Univ Bonn, Inst Med Legale, D-53111 Bonn, Germany
关键词
D O I
10.1002/rcm.945
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method combination, headspace solid-phase dynamic extraction coupled with gas chromatography/tandem mass spectrometry (HS-SPDE/GC1MS/MS), is introduced to determine drugs of abuse in hair samples. This highly automated procedure utilizes SPDE for pre-concentration and on-coating derivatization as well as GC and triple quadrupole MS/MS for selective and sensitive detection. All these steps, apart from washing and cutting of the hair samples, are performed without manual intervention on a robot-like autosampler. SPDE is a solventless extraction technique related to solid-phase microextraction (SPME). The analytes are absorbed from the sample headspace directly into a hollow needle with an internal coating of polydimethylsiloxane by repeated aspirate/dispense cycles. The HS-SPDE/GC/MS/MS procedure was applied to the analysis of methadone, the trimethylsilyl derivatives of cannabinoids and the trifluoroacetyl derivatives of amphetamines and designer drugs. The method was shown to be sensitive with detection limits between 6 and 52 pg/mg hair matrix and precision between 0.4 and 7.8% by the use of an internal standard technique. Linearity was obtained from 0.1-20 ng/mg with coefficients of correlation between 0.995 and 0.999. Compared with conventional methods of hair analysis, HS-SPDE/GC/MS/MS is easier to use, substantially faster, with the degree of sensitivity and reproducibility demanded in clinical and forensic toxicology. The main advantage of the SPDE technique in relation to SPME is the robustness of the capillary. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:472 / 478
页数:7
相关论文
共 28 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
Borth S, 2000, J MASS SPECTROM, V35, P705, DOI 10.1002/1096-9888(200006)35:6<705::AID-JMS997>3.0.CO
[3]  
2-3
[4]   Analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in biological samples by gas chromatography tandem mass spectrometry (GC/MS-MS) [J].
Chiarotti, M ;
Costamagna, L .
FORENSIC SCIENCE INTERNATIONAL, 2000, 114 (01) :1-6
[5]  
*DIN, 1994, 32645 DIN
[6]   Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography [J].
Eisert, R ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3140-3147
[7]  
Garofano L, 1998, RAPID COMMUN MASS SP, V12, P779
[9]   Determination of amphetamine and methamphetamine in human hair by headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection [J].
Koide, I ;
Noguchi, O ;
Okada, K ;
Yokoyama, A ;
Oda, H ;
Yamamoto, S ;
Kataoka, H .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :99-104
[10]   Automated solid phase dynamic extraction - Extraction of organics using a wall coated syringe needle [J].
Lipinski, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (01) :57-62