CT-angiography with a 16-row CT scanner for perioperative evaluation of the hepatic arteries

被引:6
作者
Bitschnau, S
Oberholzer, K
Kreitner, KF
Otto, G
Thelen, M
Mildenberger, P
机构
[1] Univ Mainz, Klin & Poliklin Radiol, Mainz, Germany
[2] Univ Mainz, Mainz, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2004年 / 176卷 / 11期
关键词
MSCT; hepatic arteries; perioperative diagnostic; evaluation for liver transplantation; CT/MR angiography;
D O I
10.1055/s-2004-813628
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the efficiency of CT angiography (CTA) with 16-row MSCT compared with MR angiography (MRA) in analyzing the arterial anatomy in patients undergoing liver surgery. Materials and Methods: In 30 patients, MRA and CTA studies of the abdominal vessels were reviewed. CT parameters: slice thickness 3 mm: collimation 1.5; reconstruction interval 2 mm (Philips MX 8000 IDT); 120 ml contrast media (400 mg/ml) at a rate of 4 ml/sec; acquisition of arterial-phase scans. The anatomy of the hepatic artery was evaluated from axial and reconstructed maximum-intensity-projection (MIP) images ("Slab-Viewer", Philips). MR parameters: contrast-enhanced coronal FLASH-3D sequences; slice thickness 1.4 mm; TR 3.47, TE 1.3; 1.5 T scanner (Siemens Somatom). Image quality was rated with a scoring system. Contrast enhancement of the hepatic artery and the liver parenchyma was measured. Results: The image quality of CTA was rated as excellent in 18 (MRA 5); good in 8 (MRA 22); satisfactory in 4 patients (MRA 3), and non-diagnostic in 0 patient (MRA 1). Compared to MRA, the image quality of CIA was better in 15/30 patients; equal for both in 13 and worse in 2 patients. CTA provided a better depiction of the segmental branches of the hepatic arteries in 15/30 patients and revealed important anatomic variations of the hepatic artery in 8/30 patients. These variations were not be seen in MRA: e. g., MRA missed a left gastric arterial supply to the left liver. The ratio of contrast enhancement in liver parenchyma and hepatic artery was 4.7 in CTA and 4.5 in MRA. Conclusion: CTA with multislice scanners delivers better image quality and depiction of the hepatic arteries than MRA. Thus, MRI of the hepatic arteries can be replaced by routine CT, which is already part of the preoperative evaluation for liver transplantation.
引用
收藏
页码:1634 / 1640
页数:7
相关论文
共 23 条
[1]   Accuracy and utility of 3-dimensional computed tomography in evaluating donors for adult living related liver transplants [J].
Bogetti, JD ;
Herts, BR ;
Sands, MJ ;
Carroll, JF ;
Vogt, DP ;
Henderson, JM .
LIVER TRANSPLANTATION, 2001, 7 (08) :687-692
[2]   Preoperative evaluation of the entire hepatic vasculature in living liver donors with use of contrast-enhanced MR angiography and true fast imaging with steady-state precession [J].
Carr, JC ;
Nemcek, AA ;
Abecassis, M ;
Blei, A ;
Clarke, L ;
Pereles, FS ;
McCarthy, R ;
Finn, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (04) :441-449
[3]   High-resolution CT angiography of the abdomen [J].
Catalano, C ;
Laghi, A ;
Fraioli, F ;
Pediconi, F ;
Napoli, A ;
Danti, M ;
Passariello, R .
ABDOMINAL IMAGING, 2002, 27 (05) :479-487
[4]   Preoperative evaluation of potential living donors for liver transplantation: The role of helical computed tomography-angiography [J].
Chan, JKF ;
Tso, WK ;
Lo, CM ;
Fan, ST ;
Chan, KL ;
Tam, P ;
Wei, W ;
Saing, H ;
Chau, MT ;
Leong, L ;
Chan, FL .
TRANSPLANTATION PROCEEDINGS, 1998, 30 (07) :3197-3198
[5]   Multi-row detector CT angiography of the abdominal aorta: Bolus tracking versus fixed start delay [J].
Dinkel, HP ;
Mattich, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (11) :1567-1571
[6]   Living donor liver transplantation in adults: Vascular variants important in surgical planning for donors and recipients [J].
Erbay, N ;
Raptopoulos, V ;
Pomfret, EA ;
Kamel, IR ;
Kruskal, JB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) :109-114
[7]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[8]   Multiphase hepatic CT with a multirow detector CT scanner [J].
Foley, WD ;
Mallisee, TA ;
Hohenwalter, MD ;
Wilson, CR ;
Quiroz, FA ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :679-685
[9]   Impact of multidetector CT on donor selection and surgical planning before living adult right lobe liver transplantation [J].
Kamel, IR ;
Kruskal, JB ;
Pomfret, EA ;
Keogan, MT ;
Warmbrand, G ;
Raptopoulos, V .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :193-200
[10]   Living adult right lobe liver transplantation: Imaging before surgery with multidetector multiphase CT [J].
Kamel, IR ;
Raptopoulos, V ;
Pomfret, EA ;
Kruskal, JB ;
Kane, RA ;
Yam, CS ;
Jenkins, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :1141-1143