Online condition monitoring system for substation and service transformers

被引:32
作者
Ballal, Makarand S. [1 ]
Jaiswal, Gajanan C. [2 ]
Tutkane, Dhananjay R. [3 ]
Venikar, Prasad A. [1 ]
Mishra, Mahesh Kumar [4 ]
Suryawanshi, Hiralal M. [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Elect Engn, Nagpur, Maharashtra, India
[2] Maharashtra State Elect Distribut Co Ltd, Nagpur, Maharashtra, India
[3] Shri Ramdeobaba Coll Engn & Management, Dept Elect Engn, Nagpur, Maharashtra, India
[4] Indian Inst Technol, Dept Elect Engn, Madras, Tamil Nadu, India
关键词
ASSET-MANAGEMENT; POWER TRANSFORMERS; HEALTH INDEX; RELIABILITY; PARAMETERS; FAULT;
D O I
10.1049/iet-epa.2016.0842
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Deregulation in power industry accelerates competition among various power companies. These companies are trying to gain maximum profit with minimum maintenance cost. This could be achieved by developing a condition-based monitoring product for the assessment of health of substation and service transformers. This study presents online condition monitoring system (OCMS) for transformers which is useful to replace reactive and preventive maintenance of transformers by predictive maintenance. Proposed OCMS is cost effective, online and accurate tool and it has several features like proposing corrective actions for the benefit of power utilities. Proposed system results are evaluated by comparing with the results obtained from utility model. Proposed OCMS applies only to transformers without abnormal faults such as detected by dissolved gas analysis. It is therefore very different from the other health index algorithms present in the market for condition monitoring of transformers, including in case of abnormal faults.
引用
收藏
页码:1187 / 1195
页数:9
相关论文
共 33 条
[1]   Calculation of a Health Index for Oil-Immersed Transformers Rated Under 69 kV Using Fuzzy Logic [J].
Abu-Elanien, Ahmed E. B. ;
Salama, M. M. A. ;
Ibrahim, M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) :2029-2036
[2]  
[Anonymous], 2003, IEEE STD C6241, P1, DOI DOI 10.1109/IEEESTD.2003.94253
[3]  
[Anonymous], 1986, C571101986 ANSI IEEE
[4]  
[Anonymous], REP INFR SEC EN REST
[5]  
[Anonymous], 2009, 11592009 IEEE
[6]   Investigation of Feature Selection Techniques for Improving Efficiency of Power Transformer Condition Assessment [J].
Ashkezari, Atefeh Dehghani ;
Ma, Hui ;
Saha, Tapan K. ;
Cui, Yi .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) :836-844
[7]   Interturn Faults Detection of Transformers by Diagnosis of Neutral Current [J].
Ballal, Makarand Sudhakar ;
Suryawanshi, Hiralal Murlidhar ;
Mishra, Mahesh K. ;
Chaudhari, Bhupesh Nemichand .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (03) :1096-1105
[8]  
Bhide RS, 2014, 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1542, DOI 10.1109/ICELMACH.2014.6960387
[9]   Multicriteria transformer asset management with maintenance and planning perspectives [J].
Campelo, Felipe ;
Batista, Lucas S. ;
Takahashi, Ricardo H. C. ;
Diniz, Henrique E. P. ;
Carrano, Eduardo G. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (09) :2087-2097
[10]  
Cigre W. G., 1983, ELECTRA, V88, P21