Solid Phase Extraction Method for the Determination of Cobalt in Water Samples on Duolite XAD-761 Resin Using 4-(2-Pyridylazo) Resorcinol by FAAS

被引:32
作者
Ciftci, Harun [1 ]
机构
[1] Ahi Evran Univ, Fac Arts & Sci, Dept Chem, Kirsehir, Turkey
关键词
Solid phase extraction; Duolite XAD-761; PAR; Cobalt; Metal; Preconcentration; FAAS; ATOMIC-ABSORPTION-SPECTROMETRY; AMBERLITE XAD-7; METAL-IONS; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; TRACE-ELEMENTS; OPTIMIZATION; COPPER(II); AMBERLYST-36; SEPARATION;
D O I
10.2174/157341110790945472
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A new solid-phase extraction method was developed for trace analysis of cobalt on Duolite XAD-761 resin by using flame atomic absorption spectrometry (FAAS). The optimum experimental conditions for the quantitative sorption of Co(II)-PAR (cobalt chelates with 4-(2-Pyridylazo) resorcinol), pH, effect of sample flow rate, concentration of eluent, sorption capacity of resin and the effect of diverse ions on the preconcentration of analytes have been investigated. The optimum pH values for quantitative sorption of Co (II)-PAR were between 5 and 7.5. Eluted process was performed by 4 mL ethanol. The sorption capacity of resin was determined to be 8.6 mg g(-1) for cobalt with a preconcentration factor of 150. In optimized conditions, the detection limit for cobalt ions was found to be 0.36 mu g L-1. The accuracy of the proposed procedure was checked by using NIST 1573 a tomato leave as a standard reference material. The achieved results were in good agreement with certified values. The proposed method was applied for the determination of cobalt in different water samples, such as city line, geothermal, river and lake.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 32 条
[1]
Preconcentration and matrix elimination for the determination of Pb(II), Cd(II), Ni(II), and Co(II) by 8-hydroxyquinoline anchored poly(styrene-divinylbenzene) microbeads [J].
Askun, Hakan ;
Gulbakan, Basri ;
Celikbicak, Omur ;
Uzun, Cengiz ;
Guven, Gun ;
Salih, Bekir .
JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 107 (04) :2714-2722
[2]
Cobalt [J].
Barceloux, DG .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1999, 37 (02) :201-216
[3]
Cao QE, 1999, FOOD CHEM, V65, P405, DOI 10.1016/S0308-8146(98)00222-2
[4]
On-line preconcentration of cobalt in drinking water using a minicolumn packed with activated carbon coupled to electrothermal atomic absorption spectrometric determination [J].
Cerutti, S ;
Moyano, S ;
Gásquez, JA ;
Stripeikis, J ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (11) :2015-2021
[5]
Çiftçi H, 2008, ASIAN J CHEM, V20, P3025
[6]
Çiftçi H, 2009, ASIAN J CHEM, V21, P2643
[7]
The Effect of Lipoic Acid on Macro and Trace Metal Levels in Living Tissues Exposed to Oxidative Stress [J].
Ciftci, Harun ;
Bakal, Unal .
ANTI-CANCER AGENTS IN MEDICINAL CHEMISTRY, 2009, 9 (05) :560-568
[8]
Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide [J].
Divrikli, Ü ;
Elçi, L .
ANALYTICA CHIMICA ACTA, 2002, 452 (02) :231-235
[9]
Application of Doehlert designs for optimisation of an on-line preconcentration system for copper determination by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
Bezerra, MA ;
dos Santos, WNL ;
Neto, BB .
TALANTA, 2003, 61 (03) :295-303
[10]
Simultaneous preconcentration and determination of copper, nickel, cobalt and lead ions content by flame atomic absorption spectrometry [J].
Ghaedi, Mehrorang ;
Ahmadi, Farshid ;
Shokrollahi, Ardeshir .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 142 (1-2) :272-278