Migration of the uncemented Harris-Galante acetabular cup - Results of the einbildroentgenanalyse (EBRA) method

被引:22
作者
Hendrich, C [1 ]
Bahlmann, J [1 ]
Eulert, J [1 ]
机构
[1] Univ Wurzburg, Konig Ludwig Haus, Dept Orthopaed Surg, D-97074 Wurzburg, Germany
关键词
total hip arthroplasty; acetabular cup; radiologic measurement; migration analysis; Einbildroentgen-analyse (EBRA);
D O I
10.1016/S0883-5403(97)90158-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Seventy primary total hip arthroplasties using the Harris-Galante acetabular cup (Zimmer, Warsaw, IN) were prospectively examined. Over the entire period of 65.4 +/- 7.8 months, radiologic migration analysis was performed using the Einbildroentgenanalyse (EBRA) method at an accuracy of 1 mm. Although there was clinically no suspicion of prosthetic loosening in any case, in 8 implants (11.4%) migration of more than 1 mm was observed. Cranial migration occurred in 3 cases (1.1, 1.3 and 1.6 mm), medial migration in 3 cases (1.1, 1.1, and 2.9 mm), and lateral migration in 2 cases (1.1 and 1.1 mm). In the other 62 cases, however, no migration was traceable. Compared with measurements of other implant systems by means of the EBRA method published recently by other groups, the migration rate of the Harris-Galante cup was without exception lower and provided excellent midterm implant stability.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 40 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
MIGRATION OF THE ACETABULAR SOCKET AFTER TOTAL HIP-REPLACEMENT DETERMINED BY ROENTGEN STEREOPHOTOGRAMMETRY [J].
BALDURSSON, H ;
HANSSON, LI ;
OLSSON, TH ;
SELVIK, G .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03) :535-540
[3]
TRANSGLUTEAL APPROACH TO THE HIP-JOINT [J].
BAUER, R ;
KERSCHBAUMER, F ;
POISEL, S ;
OBERTHALER, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (1-2) :47-49
[4]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]
ANATOMICAL BASIS FOR STUDY OF ACETABULAR MIGRATION OF THE PROSTHETIC CUP USED IN ARTHROPLASTY OF THE HIP - A NEW TECHNIQUE FOR MEASUREMENT OF MIGRATION [J].
COLLET, C ;
GROSDIDIER, G ;
COUDANE, H ;
BORRELLY, J .
ANATOMIA CLINICA, 1985, 7 (03) :171-173
[6]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]
DICKOB M, 1994, UNFALLCHIRURG, V97, P92
[8]
DOOLEY RL, 1992, CLIN ORTHOP RELAT R, V274, P113
[9]
ENGH CA, 1987, CLIN ORTHOP RELAT R, V231, P7
[10]
MEASUREMENT OF HIP PROSTHESES USING IMAGE-ANALYSIS - THE MAXIMA HIP TECHNIQUE [J].
HARDINGE, K ;
PORTER, ML ;
JONES, PR ;
HUKINS, DWL ;
TAYLOR, CJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :724-728