Improved measurement of iodine in food samples using inductively coupled plasma isotope dilution mass spectrometry

被引:65
作者
Haldimann, M [1 ]
Eastgate, A
Zimmerli, B
机构
[1] Swiss Fed Off Publ Hlth, Div Food Sci, CH-3003 Bern, Switzerland
[2] Glass Expans, European Off, CH-1323 Romainmotier, Switzerland
关键词
D O I
10.1039/b005879n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ICP-MS method for the determination of iodine in food samples is presented. The method makes use of a new miniature cyclonic spray chamber and a concentric glass nebulizer that is designed for low sample uptakes and is operated in a self-aspirating mode. As a consequence the wash-out was accelerated over conventional systems. This configuration allows the direct determination of iodine in mineralized solutions following digestion with nitric acid only. No strong oxidizing reagents such as perchloric acid or lengthy sample preparation were necessary to alter the chemical form of potentially volatile species. The isotope dilution technique using the long-lived isotope I-129 was applied to obtain freedom from matrix effects. The present study reports on results for total iodine in selected nutritional and biological reference materials and makes a comparison with instrumental neutron activation analysis.
引用
收藏
页码:1977 / 1982
页数:6
相关论文
共 36 条
[1]   PROPAGATION OF UNCERTAINTIES IN ISOTOPE-DILUTION MASS-SPECTROMETRY USING PULSE COUNTING DETECTION [J].
ADRIAENS, AG ;
KELLY, WR ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :660-663
[2]   THE IODINE SUPPLY OF HUMANS DEPENDING ON SITE, FOOD OFFER AND WATER-SUPPLY [J].
ANKE, M ;
GROPPEL, B ;
MULLER, M ;
SCHOLZ, E ;
KRAMER, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (1-2) :97-101
[3]  
[Anonymous], 1988, INORGANIC MASS SPECT
[4]   The Colorado thyroid disease prevalence study [J].
Canaris, GJ ;
Manowitz, NR ;
Mayor, G ;
Ridgway, EC .
ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (04) :526-534
[5]   SIMULTANEOUS DETERMINATION OF IODINE AND SELENIUM IN BIOLOGICAL SAMPLES BY RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS [J].
DERMELJ, M ;
STIBILJ, V ;
STEKAR, J ;
BYRNE, AR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04) :258-261
[6]   Where has all our iodine gone? [J].
Eastman, CJ .
MEDICAL JOURNAL OF AUSTRALIA, 1999, 171 (09) :455-456
[7]   Determination of iodine in food samples by inductively coupled plasma mass spectrometry after alkaline extraction [J].
Fecher, PA ;
Goldmann, I ;
Nagengast, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :977-982
[8]   Determination of total iodine in nutritional and biological samples by ICP-MS following their combustion within an oxygen stream [J].
Gélinas, Y ;
Krushevska, A ;
Barnes, RM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :1021-1025
[9]   Total iodine in nutritional and biological reference materials using neutron activation analysis and inductively coupled plasma mass spectrometry [J].
Gelinas, Y ;
Iyengar, GV ;
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (05) :483-488
[10]  
GRAHAM RC, 1993, DATA ANAL CHEM SCI, P268