Standard uncertainty of angular positions and statistical quality of step-scan intensity data

被引:14
作者
Rebmann, C [1 ]
Ritter, H [1 ]
Ihringer, J [1 ]
机构
[1] Univ Tubingen, Inst Kristallog, D-72070 Tubingen, Germany
来源
ACTA CRYSTALLOGRAPHICA SECTION A | 1998年 / 54卷
关键词
D O I
10.1107/S0108767397013391
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In step-scan diffraction measurements, the diffraction angle 2 theta is an observation with standard uncertainty u(2 theta). By the law of uncertainty propagation, u(2 theta), typically 0.001 < u(2 theta) < 0.004 degrees, affects the standard uncertainty u(total)(y) of the intensity y at each step 2 theta(i), depending on the local slope y'(i) = dy/d(2 theta)\(2 theta i) by u(total)(2)(y(i)) = u(Poisson)(2) + [y'(i)u(2 theta)](2), where u(Poisson) = (y(i))(1/2) is the conventional Poisson statistics. For the intensity y at 2 theta of steepest slope, u(total)(y) is given by u(total)(2)(y) = u(Poisson)(2)(1 + v(2)), where v = 2u(2 theta)y(0)(1/2)/h is the ratio of y'(i)u(2 theta) and u(Poisson) y(0) is the peak intensity and h the full :width at half-maximum of the profile. The error of the intensities at individual steps modifies also the standard uncertainty of the integrated intensity: u(total)(2)(Int) = u(Poisson)(2) (Int)(1 + v(2)/2). As v depends on y(0)(1/2)/h, it is evident that the importance of the correction increases with increasing count rates and decreasing line width. In most practical cases, y'(i)u(2 theta) contributes a multiple of Poisson statistics to the standard uncertainty of intensity. It will be shown that with a realistic weighting scheme the chi(2) as well as the Durbin-Watson test become more meaningful.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 25 条
[1]   ESDS AND ESTIMATED PROBABLE-ERROR OBTAINED IN RIETVELD REFINEMENTS WITH LOCAL CORRELATIONS [J].
BERAR, JF ;
LELANN, P .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1991, 24 :1-5
[2]  
DURBIN J, 1971, BIOMETRIKA, V58, P1
[3]  
DURBIN J, 1951, BIOMETRIKA, V38, P159, DOI 10.2307/2332325
[4]  
DURBIN J, 1950, BIOMETRIKA, V37, P409, DOI 10.1093/biomet/37.3-4.409
[5]   TESTING FOR SERIAL-CORRELATION IN INTENSITY DATA [J].
FLACK, HD ;
VINCENT, MG ;
VINCENT, JA .
ACTA CRYSTALLOGRAPHICA SECTION A, 1980, 36 (MAY) :495-496
[6]   THE EFFECT OF PROFILE STEP WIDTH ON THE DETERMINATION OF CRYSTAL-STRUCTURE PARAMETERS AND ESTIMATED STANDARD DEVIATIONS BY X-RAY RIETVELD ANALYSIS [J].
HILL, RJ ;
MADSEN, IC .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 :10-18
[7]   THE EFFECT OF PROFILE STEP COUNTING TIME ON THE DETERMINATION OF CRYSTAL-STRUCTURE PARAMETERS BY X-RAY RIETVELD ANALYSIS [J].
HILL, RJ ;
MADSEN, IC .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (OCT) :297-306
[8]   THE USE OF THE DURBIN-WATSON D-STATISTIC IN RIETVELD ANALYSIS [J].
HILL, RJ ;
FLACK, HD .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1987, 20 (05) :356-361
[9]  
HILL RJ, 1993, RIETVELD METHOD, pCH5