Wear analysis of failed acetabular polyethylene - A Comparison of analytical methods

被引:15
作者
Chuter, G. S. J. [1 ]
Cloke, D. J. [1 ]
Mahomed, A. [1 ]
Partington, P. F. [1 ]
Green, S. M. [1 ]
机构
[1] Wansbeck Gen Hosp, Dept Orthopaed, Ashington NE63 9JJ, Northd, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2007年 / 89B卷 / 02期
关键词
D O I
10.1302/0301-620X.89B2.18158
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
There are many methods for analysing wear volume in failed polyethylene acetabular components. We compared a radiological technique with three recognised ex vivo methods of measurement. We tested 18 ultra-high-molecular-weight polyethylene acetabular components revised for wear and aseptic loosening, of which 13 had pre-revision radiographs, from which the wear volume was calculated based upon the linear wear. We used a shadowgraph technique on silicone casts of all of the retrievals and a coordinate measuring method on the components directly. For these techniques, the wear vector was calculated for each component and the wear volume extrapolated using mathematical equations. The volumetric wear was also measured directly using a fluid-displacement method. The results of each technique were compared. The series had high wear volumes (mean 1385 mm 3; 730 to 1850) and high wear rates (mean 205 mm(3)/year; 92 to 363). There were wide variations in the measurements of wear volume between the radiological and the other techniques. Radiograph-derived wear volume correlated poorly with that of the fluid-displacement method, co-ordinate measuring method and shadowgraph methods, becoming less accurate as the wear increased. The mean overestimation in radiological wear volume was 47.7% of the fluid-displacement method wear volume. Fluid-displacement method, coordinate measuring method and shadowgraph determinations of wear volume were all better than that of the radiograph-derived linear measurements since they took into account the direction of wear. However, only radiological techniques can be used in vivo and remain useful for monitoring linear wear in the clinical setting. Interpretation of radiological measurements of acetabular wear must be done judiciously in the clinical setting. In vitro laboratory techniques, in particular the fluid-displacement method, remain the most accurate and reliable methods of assessing the wear of acetabular polyethylene.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 24 条
[1]
[Anonymous], CLIN ORTHOPAEDICS
[2]
BIGGS S, 1996, T 42 ORTH RES SOC M, P470
[3]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[4]
A new approach for the Martell 3-D method of measuring polyethylene wear without requiring the cross-table lateral films [J].
Bragdon, CR ;
Martell, JM ;
Estok, DM ;
Greene, ME ;
Malchau, H ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) :720-725
[5]
Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty [J].
Duffy, P ;
Sher, JL ;
Partington, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :34-38
[6]
Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro [J].
Green, TR ;
Fisher, J ;
Stone, M ;
Wroblewski, BM ;
Ingham, E .
BIOMATERIALS, 1998, 19 (24) :2297-2302
[7]
Hall R M, 1995, Proc Inst Mech Eng H, V209, P233, DOI 10.1243/PIME_PROC_1995_209_350_02
[8]
HASHIMOTO Y, 1995, T ORTHOP RES SOC, V20, P116
[9]
Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511
[10]
James SP, 1999, J BIOMED MATER RES, V48, P374, DOI 10.1002/(SICI)1097-4636(1999)48:3<374::AID-JBM23>3.0.CO