A new approach for the Martell 3-D method of measuring polyethylene wear without requiring the cross-table lateral films

被引:15
作者
Bragdon, CR [1 ]
Martell, JM
Estok, DM
Greene, ME
Malchau, H
Harris, WH
机构
[1] Massachusetts Gen Hosp, Orthopaed Biomech & Biomat Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Orthopaed Surg, Adult Reconstruct Unit, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
[4] Univ Chicago, Dept Orthopaed, Chicago, IL 60637 USA
[5] Univ Gothenburg, Inst Surg Sci, Dept Orthopaed, Gothenburg, Sweden
[6] Harvard Univ, Massachusetts Gen Hosp, Cambridge, MA 02138 USA
关键词
total hip replacement; polyethylene; wear; radiograph;
D O I
10.1016/j.orthres.2004.07.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Due to the uneven and often inadequate quality of cross-table lateral hip radiographs, many radiographic studies of femoral head penetration into polyethylene in total hip arthroplasty are limited to the two-dimensional measurement of femoral head penetration using the A/P film only. We postulated that the use of two oblique frontal projections at 90 to each other would improve the three-dimensional evaluation. Using an established hip phantom, the idealized accuracy and precision of the three-dimensional Martell method was evaluated, contrasting the standard A/P and cross-table lateral projections versus a pair of oblique projections by four independent readers. Accuracy and precision resulting from the use of two oblique projections (average accuracy +/- 63 mu m, precision +/- 26 mu m) were similar to that obtained using the conventional A/P and cross-table lateral views (accuracy +/- 54 mu m, precision +/- 22 mu m), though the results of the two oblique views were slightly more variable. These observations suggest that by using two oblique A/P projections, the major disadvantage of using the cross-table lateral films, namely the variable quality of the images, is avoided. Perhaps, therefore, the utility and availability of three-dimensional data in comparable clinical studies may be improved. (c) 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:720 / 725
页数:6
相关论文
共 21 条
[1]
Altman DG., 2013, STAT CONFIDENCE CONF
[2]
Altman DG, 1996, Practical Statistics for Medical Research
[3]
Comparison of two digital radio stereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom [J].
Bragdon, CR ;
Estok, DM ;
Malchau, H ;
Kärrholm, J ;
Yuan, XH ;
Bourne, R ;
Veldhoven, J ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :659-664
[4]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[5]
DAWSON EG, 1978, CLIN ORTHOP RELAT R, P151
[6]
Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[7]
DEVANE PA, 1999, CLIN ORTHOP RELAT R, V369, P59
[8]
Devane PA, 1995, CLIN ORTHOP RELAT R, V319, P303
[9]
MEASUREMENT OF HIP PROSTHESES USING IMAGE-ANALYSIS - THE MAXIMA HIP TECHNIQUE [J].
HARDINGE, K ;
PORTER, ML ;
JONES, PR ;
HUKINS, DWL ;
TAYLOR, CJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :724-728
[10]
Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511