Assessment of renal artery stenosis: Comparison of captopril renography and gadolinium-enhanced breath-hold MR angiography

被引:30
作者
Bongers, V
Bakker, J
Beutler, JJ
Beek, FJA
De Klerk, JMH
机构
[1] Univ Utrecht Hosp, Dept Nucl Med, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht Hosp, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[3] Univ Utrecht Hosp, Dept Nephrol, NL-3508 GA Utrecht, Netherlands
关键词
renal artery; stenosis; magnetic resonance imaging; radionuclide imaging; renal angiography;
D O I
10.1053/crad.2000.0435
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the accuracy of captopril renography (CR) and gadolinium-enhanced breathhold magnetic resonance (MR) angiography in the diagnosis of 50-99% renal artery stenosis (RAS), MATERIALS AND METHODS: Forty-three patients with possible RAS, of whom 53% had renal function impairment (creatinine >130 mu mol/l), were included, Tc-99m-mercaptoacetyl triglycine (MAG(3)) renography was performed after an oral dose of 25 mg captopril, Gadollnium-enhanced MR angiography was performed on a standard 1.5 Tesla system: TR 13.5, TE 3.5, flip angle 60 degrees, matrix 195 x 512. Intra-arterial digital subtraction angiography (DSA) was the standard of reference. RESULTS: Captropril renography accurately categorized 22 of 26 patients who had either uni- or bilateral RAS of 50-99%, The sensitivity and specificity of CR for the detection of 50-99% stenosis were 85 and 71%, respectively. With MR angiography one occluded artery was incorrectly diagnosed as a stenosis, Sensitivity and specificity were 100 and 94%, respectively. The difference between the accuracies of MR angiography and CR was statistically significant (P = 0.02). The accuracy of CR was lower in patients with renal impairment (70%) than in those with normal renal function (90%). CONCLUSION: MR angiography showed a high accuracy in diagnosing RAS of between 50 and 99%, CR was less accurate than MR angiography, especially in patients with renal function impairment, In patients with normal renal function, however, CR remains a useful diagnostic test, Bongers, V. et al. (2000). Clinical Radiology 55, 346-352 (C) 2000 The Royal College of Radiologists.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 33 条
[31]  
VENVANDE PJG, 1995, LANCET, V346, P672
[32]   Renal artery origins: Location and distribution in the transverse plane at CT [J].
Verschuyl, EJ ;
Kaatee, R ;
Beek, FJA ;
Pasterkamp, G ;
Bush, WH ;
Beutler, JJ ;
vanderVen, PJG ;
Mali, WPTM .
RADIOLOGY, 1997, 203 (01) :71-75
[33]  
Wilcox CS, 1996, SEMIN NEPHROL, V16, P43