Computer Simulations of patellofemoral joint surgery - Patient-specific models for tuberosity transfer

被引:85
作者
Cohen, ZA
Henry, JH
McCarthy, DM
Mow, VC
Ateshian, GA
机构
[1] Columbia Presbyterian Med Ctr, Dept Radiol, New York, NY 10032 USA
[2] Columbia Presbyterian Med Ctr, Dept Orthopaed Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[4] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
关键词
D O I
10.1177/03635465030310012701
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Variable clinical outcomes of tibial tuberosity transfer surgery have been reported. Hypotheses: The biomechanical outcome of surgery is patient-specific; no single procedure produces superior results for all patients. Use of patient-specific computer models can optimize choice of procedure. Study Design: Computer simulation study using clinical data. Methods: We used patient-specific multibody models of the patellofemoral joints of 20 patients with a diagnosis of patellar subluxation and osteoarthritis. Four tibial tuberosity transfer procedures (two anterior and two anteromedial) were simulated for each patient and compared with their preoperative model. Results: When results for all patients were averaged, all simulated operations produced a statistically significant decrease in surface-wide mean contact stress, although no significant difference was found among them. Conclusions: The simulated surgical outcomes were patient-specific: no single procedure was consistently superior at decreasing peak or mean stress and each procedure produced a potentially detrimental outcome, an increase in either mean stress or peak stress, in at least one patient. Clinical Relevance: Computer simulation may serve as a valuable tool for tailoring procedures to specific patients. (C) 2003 American Orthopaedic Society for Sports Medicine.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 36 条
[1]
Effects of patellar tendon adhesion to the anterior tibia on knee mechanics [J].
Ahmad, CS ;
Kwak, SD ;
Ateshian, GA ;
Warden, WH ;
Steadman, JR ;
Mow, VC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (05) :715-724
[2]
INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .2. RETROPATELLAR SURFACE [J].
AHMED, AM ;
BURKE, DL ;
YU, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :226-234
[3]
Strain patterns in the patellar tendon and the implications for patellar tendinopathy [J].
Almekinders, LC ;
Vellema, JH ;
Weinhold, PS .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (01) :2-5
[4]
Andriacchi T., 1991, BASIC ORTHOPAEDIC BI, P51
[5]
Benvenuti JF, 1997, CLIN ORTHOP RELAT R, P224
[6]
Chao E Y, 1995, Iowa Orthop J, V15, P4
[7]
SIMULATION AND ANIMATION OF MUSCULOSKELETAL JOINT SYSTEM [J].
CHAO, EYS ;
LYNCH, JD ;
VANDERPLOEG, MJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :562-568
[8]
Cohen J., 1998, Statistical Power Analysis for the Behavioral Sciences, V2nd
[9]
Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements [J].
Cohen, ZA ;
McCarthy, DM ;
Kwak, SD ;
Legrand, P ;
Fogarasi, F ;
Ciaccio, EJ ;
Ateshian, GA .
OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) :95-109
[10]
Cohen ZA, 1998, LECT NOTES COMPUT SC, V1496, P9, DOI 10.1007/BFb0056183