Evaluation of a three-dimensional micromixer in a surface-based biosensor

被引:127
作者
Vijayendran, RA
Motsegood, KM
Beebe, DJ
Leckband, DE
机构
[1] Univ Illinois, Dept Chem Engn, Urbana, IL 61801 USA
[2] Caliper Technol Corp, Mountain View, CA 94043 USA
[3] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[4] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
关键词
D O I
10.1021/la0262250
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The performance of many biosensors is limited by the rate at which a soluble analyte solution is transported to a complementary receptor immobilized on the sensor transducer. In these cases, transport limitations due to the lack of sample mixing in the sensor can impede analyte transport to the immobilized receptors and thereby reduce the sensor performance. In this study, we apply methods that have been successfully used to mix bulk fluid streams in a microfluidic device, to stir the analyte solution as it passes over receptors bound to the surface of an optical biosensor. A three-dimensional serpentine microchannel, which has been shown to provide chaotic mixing in the sample flow, was interfaced with a surface plasmon resonance biosensor. The binding kinetics of soluble rabbit IgG to protein A, immobilized on one of the microchannel walls, was measured both in the serpentine device and in a straight channel. A comparison of the initial rates of analyte detection in these two devices shows that the mixing characteristics in the serpentine microchannel can double the initial rate of analyte detection. The serpentine mixer is thus a promising method for improving the performance of surface-based microfluidic biosensors.
引用
收藏
页码:1824 / 1828
页数:5
相关论文
共 20 条
[1]  
AREF H, 1994, J FLUID MECH, V145, P1
[2]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
[3]   Fast mixing by lamination. [J].
Branebjerg, J ;
Gravesen, P ;
Krog, JP ;
Nielsen, CR .
NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, :441-446
[4]   Fluidics cube for biosensor miniaturization [J].
Dodson, JM ;
Feldstein, MJ ;
Leatzow, DM ;
Flack, LK ;
Golden, JP ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3776-3780
[5]   KINETIC-ANALYSIS OF THE INTERACTION BETWEEN PROTEIN-A DOMAIN VARIANTS AND HUMAN FC USING PLASMON RESONANCE DETECTION [J].
JENDEBERG, L ;
PERSSON, B ;
ANDERSSON, R ;
KARLSSON, R ;
UHLEN, M ;
NILSSON, B .
JOURNAL OF MOLECULAR RECOGNITION, 1995, 8 (04) :270-278
[6]   Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer [J].
Jo, BH ;
Van Lerberghe, LM ;
Motsegood, KM ;
Beebe, DJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :76-81
[7]  
JO BH, 2000, 4 INT C MIN CHEM BIO, P335
[8]   Passive mixing in a three-dimensional serpentine microchannel [J].
Liu, RH ;
Stremler, MA ;
Sharp, KV ;
Olsen, MG ;
Santiago, JG ;
Adrian, RJ ;
Aref, H ;
Beebe, DJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (02) :190-197
[9]  
McDonald JC, 2000, ELECTROPHORESIS, V21, P27, DOI 10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO
[10]  
2-C