Three-dimensional distribution of articular cartilage thickness in the elderly cadaveric acetabulum: a new method using three-dimensional digitizer and CT

被引:22
作者
Akiyama, K. [2 ]
Sakai, T. [1 ]
Koyanagi, J. [2 ]
Murase, T. [1 ]
Yoshikawa, H. [1 ]
Sugamoto, K. [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Orthopaed Biomat Sci, Suita, Osaka 5650871, Japan
关键词
Cartilage thickness; Surface registration; Proximity mapping; 3D-digitizer; Computed tomography; JOINTS; REGISTRATION; ARTHROGRAPHY; INCONGRUITY; VALIDATION; SURFACE; PROBE; HIPS;
D O I
10.1016/j.joca.2010.03.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objective The arm of this study was to evaluate the three-dimensional (3D) distribution of the acetabular articular cartilage thickness in cadaveric elderly individuals, measured using a new method with a 3D-digitizer and computed tomography (CT) and to validate this method using a thresholding technique. Design. Twenty cadaveric hemipelves without fracture, previous hip surgery, or macroscopic degenerative changes were digitized by a 3D-digitizer to make 3D cartilage surface models, and scanned by 3D-CT to create 3D bone surface models These two surface models were then merged using a surface registration method Acetabular articular cartilage thickness was evaluated as the distance between the two surface models, and the distribution was mapped Tests for accuracy and reproducibility were performed by comparing the cartilage thickness of five human femoral heads measured by stereo-microscopy with the distance between the cartilage and bone surface models. Results The superolateral cartilage tended to be the thickest in all acetabula The smallest category (0-05 mm) of articular cartilage thickness existed at the posteroinferior lunate surface In this new method, the mean measurement error was 0 018 +/- 0 044 mm for the average optimum threshold and the intraclass correlation coefficients were 099 in surface registration and 094 in data acquisition for reproducibility, indicating high accuracy and reproducibility Conclusions The proposed method for measuring articular cartilage using a 3D-digitizer and 3D-CT was accurate and reproducible. In the elderly individuals, acetabular articular cartilage tended to be thicker in the superolateral area and there was the thinnest category (0-0 5 mm) on the posteroinferior lunate sun face of the acetabulum The contour generated along 480 Hounsfield units (HU) was closest to the subchondral bone contour in the elderly hip (C) 2010 Osteoarthritis Research Society International Published by Elsevier Ltd All rights reserved
引用
收藏
页码:795 / 802
页数:8
相关论文
共 40 条
[1]
Determination of the Hounsfield value for CT-based design of custom femoral stems [J].
Aamodt, A ;
Kvistad, KA ;
Andersen, E ;
Lund-Larsen, J ;
Eine, J ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :143-147
[2]
The distribution of cartilage thickness within the joints of the lower limb of elderly individuals [J].
Adam, C ;
Eckstein, F ;
Milz, S ;
Putz, R .
JOURNAL OF ANATOMY, 1998, 193 :203-214
[3]
The distribution of cartilage thickness in the knee-joints of old-aged individuals - measurement by A-mode ultrasound [J].
Adam, C ;
Eckstein, F ;
Milz, S ;
Schulte, E ;
Becker, C ;
Putz, R .
CLINICAL BIOMECHANICS, 1998, 13 (01) :1-10
[4]
COMPARATIVE-STUDY OF THE INTRINSIC MECHANICAL-PROPERTIES OF THE HUMAN ACETABULAR AND FEMORAL-HEAD CARTILAGE [J].
ATHANASIOU, KA ;
AGARWAL, A ;
DZIDA, FJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (03) :340-349
[5]
A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[6]
Prediction of proximal femur strength using a CT-based nonlinear finite element method: Differences in predicted fracture load and site with changing load and boundary conditions [J].
Bessho, Masahiko ;
Ohnishi, Isao ;
Matsumoto, Takuya ;
Ohashi, Satoru ;
Matsuyama, Juntaro ;
Tobita, Kenji ;
Kaneko, Masako ;
Nakamura, Kozo .
BONE, 2009, 45 (02) :226-231
[7]
Eckstein F, 1997, ACTA ANAT, V158, P192
[8]
Cartilage thickness in cadaveric ankles: Measurement with double-contrast multi-detector row CT arthrography versus MR imaging [J].
El-Khoury, GY ;
Alliman, KJ ;
Lundberg, HJ ;
Rudert, MJ ;
Brown, TD ;
Saltzman, CL .
RADIOLOGY, 2004, 233 (03) :768-773
[9]
In vivo elbow biomechanical analysis during flexion: Three dimensional motion analysis using magnetic resonance imaging [J].
Goto, A ;
Moritomo, H ;
Murase, T ;
Sugamoto, K ;
Arimura, T ;
Nakajima, Y ;
Yamazaki, T ;
Sato, Y ;
Tamura, S ;
Yoshikawa, H ;
Ochi, T .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (04) :441-447
[10]
Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers [J].
Graichen, H ;
Springer, V ;
Flaman, T ;
Stammberger, T ;
Glaser, C ;
Englmeier, KH ;
Reiser, M ;
Eckstein, F .
OSTEOARTHRITIS AND CARTILAGE, 2000, 8 (02) :106-114