Postoperative sore throat and hoarseness following tracheal intubation using air or saline to inflate the cuff - A randomized controlled trial

被引:38
作者
Bennett, MH [1 ]
Isert, PR [1 ]
Cumming, RG [1 ]
机构
[1] Prince Wales Hosp, Div Anaesthesia, Sydney, NSW, Australia
关键词
INTUBATION; TRACHEAL; complications;
D O I
10.1177/0310057X0002800409
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Sore throat and hoarseness following tracheal intubation is common. The aetiology may include high tracheal cuff pressures. We performed a double-blind randomized controlled trial in 126 intubated patients to compare the incidence and severity of sore throat and hoarseness following inflation of the cliff using air or saline. Intra-cuff pressures were compared to assess any change due to inward diffusion of nitrous ox-ide. The incidence of significant sore throat and/or hoarseness overall was 15.0%. There was no statistically significant difference between the groups (air 15.9%, saline 14.5%), In the air group mean intra-cuff pressure increased significantly (start 14.0 mmHg, end 40.9 mmHg), while in the saline group there was no significant increase (start 12.7 mmHg, end 14.6 mmHg). The substitution of saline I reliably results ill sustained low intra-cuff pressure but high tracheal cuff pressure is not an important factor in the development of sore throat or hoarseness postoperatively within the pressure range and duration of operation studied.
引用
收藏
页码:408 / 413
页数:6
相关论文
共 32 条
[11]  
FLEISS JL, 1981, STATISTICAL METHODS, P260
[12]   SORE THROAT AFTER OPERATION - INFLUENCE OF TRACHEAL INTUBATION, INTRACUFF PRESSURE AND TYPE OF CUFF [J].
JENSEN, PJ ;
HOMMELGAARD, P ;
SONDERGAARD, P ;
ERIKSEN, S .
BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (04) :453-457
[13]   CONTROL OF ENDOTRACHEAL-TUBE CUFF PRESSURE USING A SIMPLE DEVICE [J].
KAY, J ;
FISHER, JA .
ANESTHESIOLOGY, 1987, 66 (02) :253-253
[14]   PRESSURES EXERTED ON TRACHEA BY ENDOTRACHEAL INFLATABLE CUFFS [J].
KNOWLSON, GT ;
BASSETT, HFM .
BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (10) :834-&
[15]   POST-OPERATIVE SORE THROAT - IMPORTANCE OF ENDOTRACHEAL-TUBE CONFORMITY VERSUS CUFF DESIGN [J].
LOESER, EA ;
MACHIN, R ;
STANLEY, TH ;
ORR, D ;
COLLEY, J ;
BENNETT, GM .
ANESTHESIOLOGY, 1978, 49 (06) :430-432
[16]   REDUCTION OF POSTOPERATIVE SORE THROAT WITH NEW ENDOTRACHEAL-TUBE CUFFS [J].
LOESER, EA ;
BENNETT, GM ;
ORR, DL ;
STANLEY, TH .
ANESTHESIOLOGY, 1980, 52 (03) :257-259
[17]   TRACHEAL PATHOLOGY FOLLOWING SHORT-TERM INTUBATION WITH LOW-PRESSURE AND HIGH-PRESSURE ENDOTRACHEAL-TUBE CUFFS [J].
LOESER, EA ;
HODGES, M ;
GLIEDMAN, J ;
STANLEY, TH ;
JOHANSEN, RK ;
YONETANI, D .
ANESTHESIA AND ANALGESIA, 1978, 57 (05) :577-579
[18]   ENDOTRACHEAL-TUBE CUFF DESIGN AND POSTOPERATIVE SORE THROAT [J].
LOESER, EA ;
ORR, DL ;
BENNETT, GM ;
STANLEY, TH .
ANESTHESIOLOGY, 1976, 45 (06) :684-687
[19]  
MANDOE H, 1992, ANESTH ANALG, V74, P897
[20]   AN ELECTROPNEUMATIC INSTRUMENT FOR MEASURING AND CONTROLLING THE PRESSURES IN THE CUFFS OF TRACHEAL TUBES - THE CARDIFF CUFF CONTROLLER [J].
MORRIS, JV ;
LATTO, IP .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1985, 9 (05) :229-230