Characterisation of epitaxial SiC Schottky barriers as particle detectors

被引:31
作者
Bruzzi, M
Lagomarsino, S
Nava, F
Sciortino, S
机构
[1] Ist Nazl Fis Nucl, I-50139 Florence, Italy
[2] Univ Florence, Dipartimento Energet, I-50139 Florence, Italy
[3] Univ Modena, Dipartimento Fis, I-41100 Modena, Italy
[4] Ist Nazl Fis Nucl, I-40126 Bologna, Italy
关键词
silicon carbide; homoepitaxy; electrical properties characterisation; detectors;
D O I
10.1016/S0925-9635(02)00350-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Epitaxial SiC devices have been tested as radiation detectors for minimum ionising particles. The devices used are based on a commercial 4H-SiC epitaxial n-type layer deposited onto a 4H-SiC n(+) type substrate wafer doped with nitrogen. Single-pad Schottky contacts have been produced by deposition of a 1000-Angstrom gold film on the epitaxial layer using a lift-off technology and ohmic contacts have been deposited on the rear substrate side. The capacitance-voltage characteristics have been measured to determine the net effective doping in the space charge layer and the maximum active thickness of the devices. The measurements showed possible non-uniformity in the net doping of the epitaxial layer. The charge collection efficiency (CCE) has been tested by means of a 0.1 mCi Sr-90 beta-source. A 100% CCE is measured at the maximum active thickness, which is achieved above approximately 400 V The charge signal of the SiC devices is stable and reproducible, with no evidence of priming or polarisation effects, due to the high crystalline quality of the epitaxial layer. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1205 / 1208
页数:4
相关论文
共 10 条
[1]   Review of the development of diamond radiation sensors [J].
Adam, W ;
Bauer, C ;
Berdermann, E ;
Bergonzo, P ;
Bogani, F ;
Borchi, E ;
Brambilla, A ;
Bruzzi, M ;
Colledani, C ;
Conway, J ;
Dabrowski, W ;
Delpierre, P ;
Deneuville, A ;
Dulinski, W ;
van Eijk, B ;
Fallou, A ;
Fizzotti, F ;
Foulon, F ;
Friedl, M ;
Gan, KK ;
Gheeraert, E ;
Grigoriev, E ;
Hallewell, G ;
Hall-Wilton, R ;
Han, S ;
Hartjes, F ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kaplon, J ;
Karl, C ;
Kass, R ;
Knöpfle, KT ;
Krammer, M ;
Logiudice, A ;
Lu, R ;
Manfredi, PF ;
Manfredotti, C ;
Marshall, RD ;
Meier, D ;
Mishina, M ;
Oh, A ;
Pan, LS ;
Palmieri, VG ;
Pernicka, M ;
Peitz, A ;
Pirollo, S ;
Polesello, P ;
Pretzl, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01) :131-145
[2]   High quality SiC applications in radiation dosimetry [J].
Bruzzi, M ;
Nava, F ;
Pini, S ;
Russo, S .
APPLIED SURFACE SCIENCE, 2001, 184 (1-4) :425-430
[3]   Characterisation of silicon carbide detectors response to electron and photon irradiation [J].
Bruzzi, M ;
Nava, F ;
Russo, S ;
Sciortino, S ;
Vanni, P .
DIAMOND AND RELATED MATERIALS, 2001, 10 (3-7) :657-661
[4]   Radiation damage in silicon detectors for high-energy physics experiments [J].
Bruzzi, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :960-971
[5]  
NAVA F, UNPUB NUCL INSTRUM A
[6]   CHARACTERISTICS OF SILICON DIODES AS PATIENT DOSIMETERS IN EXTERNAL RADIATION-THERAPY [J].
NILSSON, B ;
RUDEN, BI ;
SORCINI, B .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (03) :279-288
[7]  
*RD50 COLL, LHCC 2002 003 15 FEB
[8]   Particle detectors based on semi-insulating silicon carbide [J].
Rogalla, M ;
Runge, K ;
Söldner-Rembold, A .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 :516-520
[9]   Investigation on the charge collection properties of a 4H-SiC Schottky diode detector [J].
Verzellesi, G ;
Vanni, P ;
Nava, F ;
Canali, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03) :717-721
[10]   Growth of silicon carbide:: process-related defects [J].
Yakimova, R ;
Syväjarvi, M ;
Iakimov, T ;
Jacobsson, H ;
Kakanakova-Georgieva, A ;
Råback, P ;
Janzén, E .
APPLIED SURFACE SCIENCE, 2001, 184 (1-4) :27-36