MRI of fistula-in-ano: A comparison of endoanal coil with external phased array coil techniques

被引:61
作者
deSouza, NM [1 ]
Gilderdale, DJ [1 ]
Coutts, GA [1 ]
Puni, R [1 ]
Steiner, RE [1 ]
机构
[1] Hammersmith Hosp, Royal Postgrad Med Sch, Robert Steiner Magnet Resonance Unit, London W12 0HS, England
基金
英国惠康基金;
关键词
fistula and fistulas; magnetic resonance imaging; apparatus and equipment; gastrointestinal tract diseases;
D O I
10.1097/00004728-199805000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of our study was to compare MRI of fistulas-in-ano using an endoanal coil with that using a pelvic phased array coil and to assess the value of a combined approach by correlating the findings with those at surgery. Method: Twenty consecutive patients with clinical suspicion of perianal sepsis were studied using an endoanal coil immediately followed by a phased array coil. T1 weighted and STIR images in transverse and coronal planes were made with each coil and analysed by noting the presence and site of a collection and primary track, the position of any internal opening, and subcutaneous or supralevator extension. Operative findings were similarly recorded. Results: Of 20 patients with suspected fistulas, 8 had simple fistulas, 8 had complex fistulas, and 4 had no current evidence of infection. The concordance between MR and surgery for identifying the presence and site of the collection, the primary track, and the internal opening in both simple and complex cases was superior using the endoanal coil as compared with the phased array. Both coils together reflected the findings of the endoanal coil used alone. However, for supralevator/subcutaneous extension, concordance was superior using the phased array compared with the endoanal coil, and a combined approach reflected the values of the phased array coil used alone. Conclusion: Endoanal MRT is highly sensitive in the delineation of fistulas-in-ano. In combination with phased array techniques, it provides valuable preoperative assessment in both simple and complex cases.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 13 条
[1]   MAGNETIC-RESONANCE-IMAGING OF FISTULA-IN-ANO - TECHNIQUE, INTERPRETATION AND ACCURACY [J].
BARKER, PG ;
LUNNISS, PJ ;
ARMSTRONG, P ;
REZNEK, RH ;
COTTAM, K ;
PHILLIPS, RK .
CLINICAL RADIOLOGY, 1994, 49 (01) :7-13
[2]  
BYDDER G M, 1985, Magnetic Resonance Imaging, V3, P251, DOI 10.1016/0730-725X(85)90354-6
[3]   COMPARISON BETWEEN ANAL ENDOSONOGRAPHY AND DIGITAL EXAMINATION IN THE EVALUATION OF ANAL FISTULAS [J].
CHOEN, S ;
BURNETT, S ;
BARTRAM, CI ;
NICHOLLS, RJ .
BRITISH JOURNAL OF SURGERY, 1991, 78 (04) :445-447
[4]   High resolution magnetic resonance imaging of the anal sphincter using a dedicated endoanal coil - Comparison of magnetic resonance imaging with surgical findings [J].
deSouza, NM ;
Hall, AS ;
Puni, R ;
Gilderdale, DJ ;
Young, IR ;
Kmiot, WA .
DISEASES OF THE COLON & RECTUM, 1996, 39 (08) :926-934
[5]   MRI OF THE ANAL-SPHINCTER [J].
DESOUZA, NM ;
PUNI, R ;
KMIOT, WA ;
BARTRAM, CI ;
HALL, AS ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (05) :745-751
[6]   HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE ANAL-SPHINCTER USING AN INTERNAL COIL [J].
DESOUZA, NM ;
KMIOT, WA ;
PUNI, R ;
HALL, AS ;
BURL, M ;
BARTRAM, CI ;
BYDDER, GM .
GUT, 1995, 37 (02) :284-287
[7]   ANAL ENDOSONOGRAPHY IN THE EVALUATION OF PERIANAL SEPSIS AND FISTULA INANO [J].
LAW, PJ ;
TALBOT, RW ;
BARTRAM, CI ;
NORTHOVER, JMA .
BRITISH JOURNAL OF SURGERY, 1989, 76 (07) :752-755
[8]   MAGNETIC-RESONANCE-IMAGING OF ANAL FISTULAS [J].
LUNNISS, PJ ;
ARMSTRONG, P ;
BARKER, PG ;
REZNEK, RH ;
PHILLIPS, RKS .
LANCET, 1992, 340 (8816) :394-396
[9]   ANAL FISTULAS AT ST MARKS HOSPITAL [J].
MARKS, CG ;
RITCHIE, JK .
BRITISH JOURNAL OF SURGERY, 1977, 64 (02) :84-91
[10]   PERIANAL FISTULAS - USE OF MR-IMAGING FOR DIAGNOSIS [J].
MYHR, GE ;
MYRVOLD, HE ;
NILSEN, G ;
THORESEN, JE ;
RINCK, PA .
RADIOLOGY, 1994, 191 (02) :545-549