Investigation of a flat sheet membrane desolvator for aqueous solvent removal with inductively coupled plasma atomic emission spectrometry

被引:10
作者
Akinbo, OT [1 ]
Carnahan, JW [1 ]
机构
[1] NO ILLINOIS UNIV,DEPT CHEM,DE KALB,IL 60115
关键词
flat sheet membrane desolvator; sample introduction; atomic emission spectrometry; analyte transport; preconcentration;
D O I
10.1016/S0039-9140(97)00112-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results obtained from a preliminary investigation of the performance of a flat sheet membrane desolvator (FSMD) utilizing dual hydrophobic polypropylene membranes with an average pore size of 0.05 mu m and a 50 +/- 5 mu m thickness are reported. The membranes have a desolvation area of 241 cm(2). The volume-to-surface area ratio is 0.3 cm. Using the FSMD with an ultrasonic nebulizer (USN), aqueous solvent desolvation efficiencies of greater than 99.9% were obtained at all nebulizer gas flow rates investigated (0.8, 1.2, and 1.8 1 min(-1)). This efficient desolvation occurred when the countercurrent gas flow rate was equal to or slightly greater than the applied nebulizer gas flow rate. Under these conditions preconcentration factors of 18, 44, and 590 were observed with flows of 0.8, 1.2 and 1.8 1 min(-1), respectively. Operating with countercurrent gas flow rates much higher than the nebulizer gas flow rates leads to a significant reduction in analyte flux, thus increasing detection limits. Depending on the nebulizer and countercurrent gas flow rate conditions, the FSMD contributed between 10-40% to the overall analyte loss in the system. The lowest detection limit observed for aqueous copper with the USN-FSMD system is 0.4 ppb at nebulizer and countercurrent gas flow rates of 1.2 and 1.4 1 min(-1), respectively. At this nebulizer gas flow rate, replacing the FSMD in the system with a commercial tubular membrane desolvator, MDX100, gave a lowest Cu detection limit of 0.2 ppb at a countercurrent gas flow rate of 1.2 1 min(-1). These detection limits represents improvements over the 0.7 and 8 ppb obtained with USN and pneumatic nebulization, respectively. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 22 条
[1]   REMOVAL OF ORGANIC-SOLVENTS BY CRYOGENIC DESOLVATION IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
ALVES, LC ;
MINNICH, MG ;
WIEDERIN, DR ;
HOUK, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :399-403
[2]   A MEMBRANE INTERFACE FOR ORGANIC-SOLVENT SAMPLE INTRODUCTION INTO INDUCTIVELY COUPLED PLASMAS [J].
BACKSTROM, K ;
GUSTAVSSON, A ;
HIETALA, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (10) :1041-1048
[3]   USE OF AN ULTRASONIC NEBULIZER WITH MEMBRANE DESOLVATION FOR ANALYSIS OF VOLATILE SOLVENTS BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
BOTTO, RI ;
ZHU, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :905-912
[4]   HYDRIDE INTERFERENCE ON THE DETERMINATION OF MINOR ACTINIDE ISOTOPES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CRAIN, JS ;
ALVARADO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1223-1227
[5]  
GUSTAVSON A, 1987, SPECTROCHIM ACTA B, V42, P113
[6]   A MEMBRANE INTERFACE FOR AQUEOUS SAMPLE INTRODUCTION INTO INDUCTIVELY COUPLED PLASMAS [J].
GUSTAVSSON, A ;
HIETALA, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (10) :1103-1108
[8]   DETERMINATION OF TRACE-METALS IN VOLATILE ORGANIC-SOLVENTS USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HILL, SJ ;
HARTLEY, J ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (01) :23-28
[9]   INDUCTIVELY COUPLED ARGON PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRIC DETERMINATION OF TRACE-ELEMENTS [J].
HOUK, RS ;
FASSEL, VA ;
FLESCH, GD ;
SVEC, HJ ;
GRAY, AL ;
TAYLOR, CE .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2283-2289
[10]   ROLE OF AEROSOL WATER-VAPOR LOADING IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) :595-598