Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery

被引:47
作者
Kubo, HD [1 ]
Wang, LL [1 ]
机构
[1] Univ Calif Davis, Ctr Canc, Dept Radiat Oncol, Sacramento, CA 95817 USA
关键词
gated radiotherapy; linear accelerator; enhanced dynamic wedge; IMRT;
D O I
10.1118/1.1287110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An enhanced dynamic wedge (EDW) is one of the latest technical innovations frequently used in the radiotherapy department. Its usage is enthusiastically supported by radiation therapists. Intensity modulated radiotherapy (IMRT) is the other, which has become popular within the past several years. Its usage is not as straightforward as the EDW. However, its ability to further increase dose conformity to the target and to spare the surrounding normal tissues has been evidenced. Both of these treatment modalities demand sophisticated software, which controls precision motion and speed of jaws or multileaf collimators as well as dose rate. This paper deals with the question of how accurately the EDW profiles and IMRT dose distributions be maintained when the additional constraint of linear accelerator gating is invoked. For this, square pulses mimicking breathing were used in gated and nongated modes for film dosimetry and ion chamber measurements using the Varian 2100C linear accelerator. The results show no observable difference between gated and nongated EDW profiles and IMRT dose distribution regardless of the machine repetition rate. Also studied in this paper an the "fuzzy" dose distributions caused by realistic finite gate window settings. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)02108-8].
引用
收藏
页码:1732 / 1738
页数:7
相关论文
共 20 条
[1]   Intensity-modulated radiation therapy with dynamic multileaf collimators [J].
Boyer, AL ;
Yu, CX .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :48-59
[2]  
Edlund T, 1999, Med Dosim, V24, P21, DOI 10.1016/S0958-3947(98)00047-8
[3]   Optimization and clinical use of multisegment intensity-modulated radiation therapy for high-dose conformal therapy [J].
Fraass, BA ;
Kessler, ML ;
McShan, DL ;
Marsh, LH ;
Watson, BA ;
Dusseau, WJ ;
Eisbruch, A ;
Sandler, HM ;
Lichter, AS .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :60-+
[4]   Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields [J].
Gibbons, JP .
MEDICAL PHYSICS, 1998, 25 (08) :1411-1418
[5]   Clinical and financial issues for intensity-modulated radiation therapy delivery [J].
Grant, W ;
Woo, SY .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :99-+
[6]   Intensity-modulated tangential beam irradiation of the intact breast [J].
Hong, L ;
Hunt, M ;
Chui, C ;
Spirou, S ;
Forster, K ;
Lee, H ;
Yahalom, J ;
Kutcher, GJ ;
McCormick, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1155-1164
[7]   Multiple machine implementation of enhanced dynamic wedge [J].
Klein, EE ;
Gerber, R ;
Zhu, XR ;
Oehmke, F ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04) :977-985
[8]  
Kubo H. D., 1999, International Journal of Radiation Oncology Biology Physics, V45, P204, DOI 10.1016/S0360-3016(99)90129-3
[9]   Potential and role of a prototype amorphous silicon array electronic portal imaging device in breathing synchronized radiotherapy [J].
Kubo, HD ;
Shapiro, EG ;
Seppi, EJ .
MEDICAL PHYSICS, 1999, 26 (11) :2410-2414
[10]   Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353