A signal processing model for arterial spin labeling functional MRI

被引:185
作者
Liu, TT
Wong, EC
机构
[1] Univ Calif San Diego, Ctr Funct MRI, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
关键词
fMRI; perfusion; arterial spin labeling; BOLD;
D O I
10.1016/j.neuroimage.2004.09.047
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A model of the signal path in arterial spin labeling (ASL)-based functional magnetic resonance imaging (fMRI) is presented. Three subtraction-based methods for forming a perfusion estimate are considered and shown to be specific cases of a generalized estimate consisting of a modulator followed by a low pass filter. The performance of the methods is evaluated using the signal model. Contamination of the perfusion estimate by blood oxygenation level dependent contrast (BOLD) is minimized by using either sine subtraction or surround subtraction for block design experiments and by using pair-wise subtraction for randomized event-related experiments. The subtraction methods all tend to decorrelate the 1/f type low frequency noise often observed in fMRI experiments. Sine subtraction provides the flattest noise power spectrum at low frequencies, while pair-wise subtraction yields the narrowest autocorrelation function. The formation of BOLD estimates from the ASL data is also considered and perfusion weighting of the estimates is examined using the signal model. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 28 条
[1]   Experimental design and the relative sensitivity of BOLD and perfusion fMRI [J].
Aguirre, GK ;
Detre, JA ;
Zarahn, E ;
Alsop, DC .
NEUROIMAGE, 2002, 15 (03) :488-500
[2]  
Alsop DC., 2000, P INT SOC MAGN RES M, P162
[3]  
Blamire AM, 2000, MAGNET RESON MED, V43, P701, DOI 10.1002/(SICI)1522-2594(200005)43:5<701::AID-MRM12>3.0.CO
[4]  
2-Y
[5]  
Bracewell R.N., 1965, The Fourier Transform and Its Applications
[6]  
Burock MA, 2000, HUM BRAIN MAPP, V11, P249, DOI 10.1002/1097-0193(200012)11:4<249::AID-HBM20>3.0.CO
[7]  
2-5
[8]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864
[9]   Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain [J].
Duhamel, G ;
de Bazelaire, U ;
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :145-153
[10]   Localized cerebral blood flow response at submillimeter columnar resolution [J].
Duong, TQ ;
Kim, DS ;
Ugurbil, K ;
Kim, SG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (19) :10904-10909