Rapid image stitching and computer-aided detection for multipass automated breast ultrasound

被引:30
作者
Chang, Ruey-Feng [2 ]
Chang-Chien, Kuang-Che [3 ]
Takada, Etsuo [4 ]
Huang, Chiun-Sheng [5 ,6 ]
Chou, Yi-Hong [7 ]
Kuo, Chen-Ming [3 ]
Chen, Jeon-Hor [1 ]
机构
[1] China Med Univ Hosp, Dept Radiol, Taichung 40407, Taiwan
[2] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Grad Inst Biomed Elect & Bioinformat, Taipei 10617, Taiwan
[3] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi 621, Taiwan
[4] Dokkyo Med Univ, Sch Med, Div Med Ultrason, Ctr Opt Med, Mibu, Tochigi 3210293, Japan
[5] Natl Taiwan Univ Hosp, Dept Surg, Taipei 100, Taiwan
[6] Natl Taiwan Univ, Coll Med, Taipei 100, Taiwan
[7] Natl Yang Ming Univ, Sch Med, Taipei Vet Gen Hosp, Dept Radiol, Taipei 11217, Taiwan
关键词
biological organs; biomedical ultrasonics; CAD; cancer; gynaecology; mammography; ELEVATED RISK; DENSE BREAST; WOMEN; REGISTRATION; DIAGNOSIS; MAMMOGRAPHY; TUMOR; ULTRASONOGRAPHY; PERFORMANCE; CARCINOMA;
D O I
10.1118/1.3377775
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: Using the registration technique based on the simple sum of absolute block-mean difference (SBMD) measure, three-pass images were merged into full-view US images. An automatic screening system was then developed for detecting tumors from these full-view images. The preprocessing step was used to reduce the tumor detection time of the system and to improve image quality. The gray-level slicing method was then used to divide images into numerous regions. Finally, seven computerized features-darkness, uniformity, width-height ratio, area size, nonpersistence, coronal area size, and region continuity-were defined and used to determine whether or not each region was a part of a tumor. Results: In the experiment, there was a total of 25 experimental cases with 26 lesions, and each case was composed of 252 images (three passes, 84 images/pass). The processing time of the proposed stitching procedure for each case was within 30 s with a Pentium IV 2.0 processor, and the detection sensitivity of the proposed CAD system was 92.3% with 1.76 false positives per case. Conclusions: The proposed automatic screening system can be applied to the whole breast images stitched together via SBMD-based registration in order to detect tumors.
引用
收藏
页码:2063 / 2073
页数:11
相关论文
共 49 条
[1]   On the estimation of the coefficient of variation for anisotropic diffusion speckle filtering [J].
Aja-Fernandez, Santiago ;
Alberola-Lopez, Carlos .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (09) :2694-2701
[2]   Computer vision techniques for breast tumor ultrasound analysis [J].
Aleman-Flores, Miguel ;
Aleman-Flores, Patricia ;
Alvarez-Leon, Luis ;
Fuentes-Pavon, Rafael ;
Santana-Montesdeoca, Jose M. .
BREAST JOURNAL, 2008, 14 (05) :483-486
[3]   Complexity curve and grey level co-occurrence matrix in the texture evaluation of breast tumor on ultrasound images [J].
Alvarenga, Andre Victor ;
Pereira, Wagner C. A. ;
Infantosi, Antonio Fernando C. ;
Azevedo, Carolina M. .
MEDICAL PHYSICS, 2007, 34 (02) :379-387
[4]  
[Anonymous], 2009, Breast cancer facts and figures 2009
[5]   Computer-based detection and prompting of mammographic abnormalities [J].
Astley, SM .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S194-S200
[6]  
Berg WA, 2007, 6666 ACRIN
[7]   Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Cormack, Jean B. ;
Mendelson, Ellen B. ;
Lehrer, Daniel ;
Bohm-Velez, Marcela ;
Pisano, Etta D. ;
Jong, Roberta A. ;
Evans, W. Phil ;
Morton, Marilyn J. ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Barr, Richard G. ;
Farria, Dione M. ;
Marques, Helga S. ;
Boparai, Karan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (18) :2151-2163
[8]   Mammography screening matters for young women with breast carcinoma - Evidence of downstaging among 42-49-year-old women with a history of previous mammography screening [J].
Buseman, S ;
Mouchawar, J ;
Calonge, N ;
Byers, T .
CANCER, 2003, 97 (02) :352-358
[9]   Diffuse boundary extraction of breast masses on ultrasound by leak plugging [J].
Cary, TW ;
Conant, EF ;
Arger, PH ;
Sehgal, CM .
MEDICAL PHYSICS, 2005, 32 (11) :3318-3328
[10]   Statistical power in observer-performance studies: Comparison of the receiver operating characteristic and free-response methods in tasks involving localization [J].
Chakraborty, D .