The anterior and medial reduction of intertrochanteric fractures: A simple method to obtain a stable reduction

被引:66
作者
Carr, James B.
机构
[1] Univ S Carolina, Columbia, SC 29208 USA
[2] Palmetto Hlth Richland Hosp, Columbia, SC USA
关键词
intertrochanteric hip fracture; reduction techniques;
D O I
10.1097/BOT.0b013e31804797cf
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This article describes a simple method using anterior and media bone contact of the distal shaft piece to obtain a stable reduction for displaced intertrochanteric fractures of the hip. The technique is based on the observation that the anterior pathoanatomy of the intertrochanteric hip fracture involves a noncomminuted fracture plane that can be placed into contact. This reestablishes a normal neck shaft angle and prevents excessive collapse of the fracture site. The maneuver is described in the context of the fracture pathoanatomy and the use of a fracture table.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 28 条
[1]
Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]
APEL DM, 1989, CLIN ORTHOP RELAT R, P156
[3]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[4]
BAUMGAERTNER MR, 1998, SKELETAL TRAUMA, P1852
[5]
Bendo J A, 1994, Orthop Rev, VSuppl, P30
[6]
Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate [J].
Bolhofner, BR ;
Russo, PR ;
Carmen, B .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (01) :5-8
[7]
HAS-plate versus sliding hill screw fer unstable trochanteric hip fractures: Stability of the fixation and modes of failure - Radiographic analysis of 218 fractures [J].
Buciuto, R ;
Hammer, R .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (03) :545-550
[8]
TREATMENT OF THE UNSTABLE INTERTROCHANTERIC FRACTURE - EFFECT OF THE PLACEMENT OF THE SCREW, ITS ANGLE OF INSERTION, AND OSTEOTOMY [J].
DENHARTOG, BD ;
BARTAL, E ;
COOKE, F .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (05) :726-733
[9]
UNSTABLE INTERTROCHANTERIC FRACTURE OF THE FEMUR - A PROSPECTIVE RANDOMIZED STUDY COMPARING ANATOMICAL REDUCTION AND MEDIAL DISPLACEMENT OSTEOTOMY [J].
DESJARDINS, AL ;
ROY, A ;
PAIEMENT, G ;
NEWMAN, N ;
PEDLOW, F ;
DESLOGES, D ;
TURCOTTE, RE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :445-447
[10]
Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures [J].
Elder, S ;
Frankenburg, E ;
Goulet, J ;
Yetkinler, D ;
Poser, R ;
Goldstein, S .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) :386-393