Flow cytometric quantitation of yeast a novel technique for use in animal model work and in vitro immunologic assays

被引:22
作者
Chang, WL
van der Heyde, HC
Klein, BS
机构
[1] Univ Wisconsin Hosp & Clin, Sch Med, Dept Internal Med, Madison, WI 53792 USA
[2] Univ Wisconsin Hosp & Clin, Sch Med, Dept Med Microbiol & Immunol, Madison, WI 53792 USA
[3] Univ Wisconsin Hosp & Clin, Sch Med, Dept Pediat, Madison, WI 53792 USA
[4] Univ Wisconsin Hosp & Clin, Sch Med, Ctr Comprehens Canc, Madison, WI 53792 USA
关键词
quantitation; yeast burden; flow cytometry; viability;
D O I
10.1016/S0022-1759(97)00191-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Animal models of fungal and other infectious diseases often require that the number of organisms in tissue be quantified, traditionally by grinding organs, plating them on agar and counting colony forming units (CFU). This method is labor intensive, slow as some fungi require two weeks of culture and limited in reliability by poor plating efficiency. To circumvent these problems, we developed a flow cytometric method to quantify yeast. In vitro cultured Blastomyces dermatitidis, Cryptococcus neoformans, Candida albicans and Histoplasma capsulatum yeast were labelled with specific monoclonal or polyclonal antibodies to stain surface determinants or with Calcofluor to stain cell-wall chitin, A defined number of fluorescently labelled beads were added prior to acquisition by flow cytometry as a reference standard for quantitation. Beads were readily distinguished from yeast by forward scatter, side scatter and intensity of fluorescence. Cultured yeast were enumerated by both standard CFU determination and flow cytometry in a range of 10(2) to 10(7) cells. Only flow cytometry enabled discrimination of live and dead yeast by using appropriate fluorescent dyes. The flow cytometric method was applied to murine models of histoplasmosis and blastomycosis to quantify the burden of fungi in the lungs of infected mice. Labelling yeast with Calcofluor alone resulted in unacceptably high levels of nonspecific binding to mouse cell debris. In contrast, labelling H. capsulatum with a rabbit polyclonal antiserum and B. dermatitidis with a monoclonal antibody to the surface protein WI-1 permitted accurate quantitation. We conclude that this flow cytometry technique is rapid, efficient and reliable for quantifying the burden of infection in animal models of fungal disease. The technique also should lend itself to performing cytotoxicity assays that require discrimination of live and dead fungi, or phagocytosis assays that require discrimination of intracellular and extracellular organisms. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:51 / 63
页数:13
相关论文
共 14 条
[1]   A RAPID ANALYTICAL TECHNIQUE FOR FLOW CYTOMETRIC ANALYSIS OF CELL VIABILITY USING CALCOFLUOR WHITE M2R [J].
BERGLUND, DL ;
TAFFS, RE ;
ROBERTSON, NP .
CYTOMETRY, 1987, 8 (04) :421-426
[3]   QUANTITATIVE-ANALYSIS OF PHAGOCYTOSIS AND KILLING OF CRYPTOCOCCUS-NEOFORMANS BY HUMAN PERIPHERAL-BLOOD MONONUCLEAR-CELLS BY FLOW-CYTOMETRY [J].
CHAKA, W ;
SCHARRINGA, J ;
VERHEUL, AFM ;
VERHOEF, J ;
VANSTRIJP, AG ;
HOEPELMAN, IM .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1995, 2 (06) :753-759
[4]  
COLIGAN JE, 1994, CURRENT PROTOCOLS IM, V1
[5]   NEW, SIMPLE FLOW-CYTOMETRY TECHNIQUE TO DISCRIMINATE BETWEEN INTERNALIZED AND MEMBRANE-BOUND PARTICLES IN PHAGOCYTOSIS [J].
FATTOROSSI, A ;
NISINI, R ;
PIZZOLO, JG ;
DAMELIO, R .
CYTOMETRY, 1989, 10 (03) :320-325
[6]   RAPID-DETERMINATION OF ANTIFUNGAL ACTIVITY BY FLOW-CYTOMETRY [J].
GREEN, L ;
PETERSEN, B ;
STEIMEL, L ;
HAEBER, P ;
CURRENT, W .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (04) :1088-1091
[7]  
Hageage G. J. Jr., 1984, Laboratory Medicine, V15, P109
[9]   Rapid susceptibility testing of Candida albicans by flow cytometry [J].
Kirk, SM ;
Callister, SM ;
Lim, LCL ;
Schell, RF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (02) :358-363
[10]   RAPID FLOW CYTOFLUOROMETRIC ANALYSIS OF MAMMALIAN-CELL CYCLE BY PROPIDIUM IODIDE STAINING [J].
KRISHAN, A .
JOURNAL OF CELL BIOLOGY, 1975, 66 (01) :188-193