Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model

被引:104
作者
Leung, F [1 ]
Zhu, L
Ho, H
Lu, WW
Chow, SP
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Orthopaed Surg, HK SAR, Hong Kong, Hong Kong, Peoples R China
[2] First Mil Med Univ Nanfang Hosp, Dept Orthopaed & Traumatol, Guangzhou 510515, Peoples R China
关键词
D O I
10.1016/S0266-7681(03)00011-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional palmar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the palmar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.
引用
收藏
页码:263 / 266
页数:4
相关论文
共 16 条
[1]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[3]
Chow, 1999, Hand Surg, V4, P175, DOI 10.1142/S0218810499000381
[4]
GRAFF S, 1994, INJURY S4, V25, P15
[5]
CLINICAL AND MICROANGIOGRAPHIC STUDIES ON RUPTURE OF THE EPL TENDON AFTER DISTAL RADIAL FRACTURES [J].
HIRASAWA, Y ;
KATSUMI, Y ;
AKIYOSHI, T ;
TAMAI, K ;
TOKIOKA, T .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1990, 15B (01) :51-57
[6]
Open reduction and internal fixation of displaced intraarticular fractures of the distal radius - 31 patients followed for 3-7 years [J].
Hove, LM ;
Nilsen, PT ;
Furnes, O ;
Oulie, HE ;
Solheim, E ;
Molster, AO .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (01) :59-63
[7]
FRACTURES OF THE DISTAL END OF THE RADIUS [J].
JUPITER, JB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03) :461-469
[8]
KAMANO M, 2002, CLIN ORTHOP RELAT R, V397, P403
[9]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[10]
Leung F, 2000, Hand Surg, V5, P145, DOI 10.1142/S0218810400000338