Vibration of the cantilever in Force Modulation Microscopy analysis by a finite element model

被引:25
作者
Arinero, R [1 ]
Lévêque, G [1 ]
机构
[1] Univ Montpellier 2, Lab Anal Interfaces & Nanophys, UMR 5011, CNRS, F-34095 Montpellier 5, France
关键词
D O I
10.1063/1.1525874
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The resonance frequency of the cantilever beam of a Force Modulation Microscope is studied in function of the beam shape, the sample stiffness, and the contact model. We used a one dimensional finite element model for the cantilever beam, which permits the exact vibration of the beam to be treated in the contact mode, whatever its shape (rectangular as well as triangular beams) and excitation mode (by the beam holder, by the sample, by a localized, or distributed force). Based on a classic finite element scheme, it is simple to program and as rapid as the usual analytical models. We demonstrate that the mode of excitation of the beam strongly influences the cantilever's frequency response in the contact mode. Anti-resonance is observed on the amplitude curves, which may perturb the measurements on some samples. We analyzed the true normal and tangential amplitude, for different beams and tip dimensions, in relation with the apparent amplitude of the vibration, as detected by the system. Experimental results on soft materials (polyurethane rubbers) give evidence of a nonsliding contact and underline the importance of an adequate treatment for the tangential forces, even in the linear domain. We assume a kind of viscosity of the contact, the effects of which are not visible for slow scan, but stick the tip and the sample together in the 10-100 kHz frequency range. This viscosity also induces an important damping of the resonance. (C) 2003 American Institute of Physics.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 26 条
[1]   Modelling the adhesion of spheres: when the form of the interaction is complex [J].
Barthel, E .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1999, 149 (1-3) :99-105
[2]   Materials' properties measurements: Choosing the optimal scanning probe microscope configuration [J].
Burnham, NA ;
Gremaud, G ;
Kulik, AJ ;
Gallo, PJ ;
Oulevey, F .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02) :1308-1312
[3]   A general equation for fitting contact area and friction vs load measurements [J].
Carpick, RW ;
Ogletree, DF ;
Salmeron, M .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 211 (02) :395-400
[4]  
DROUIN B, 1993, MECANIQUE VIBRATOIRE
[5]   High-frequency mechanical spectroscopy with an atomic force microscope [J].
Dupas, E ;
Gremaud, G ;
Kulik, A ;
Loubet, JL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (10) :3891-3897
[6]  
Johnson K. L., 1987, CONTACT MECH
[7]  
Maugis D., 2000, Contact, Adhesion, and Rupture of Elastic Solids
[8]   Normal and lateral modulation with a scanning force microscope, an analysis: implication in quantitative elastic and friction imaging [J].
Mazeran, PE ;
Loubet, JL .
TRIBOLOGY LETTERS, 1999, 7 (04) :199-212
[9]   Force modulation with a scanning force microscope: an analysis [J].
Mazeran, Pierre-Emmanuel ;
Loubet, Jean-Luc .
TRIBOLOGY LETTERS, 1997, 3 (01) :125-132
[10]   A method of evaluating local elasticity and adhesion energy from the nonlinear response of AFM cantilever vibrations [J].
Muraoka, M ;
Arnold, W .