Development of an ICP-IDMS method for accurate routine analyses of toxic heavy metals in polyolefins and comparison with results by TI-IDMS

被引:20
作者
Diemer, J [1 ]
Heumann, KG [1 ]
机构
[1] Univ Mainz, Inst Inorgan Chem & Analyt Chem, D-55099 Mainz, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 368卷 / 01期
关键词
D O I
10.1007/s002160000469
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method was developed as a suitable method - with respect to its sensitivity, precision, accuracy, and time-consumption - for the analysis of toxic heavy metal traces (Pb, Cd, Cr, and Hg) in polyolefins. Results for Pb, Cd, and Cr were compared with those obtained by thermal ionization isotope dilution mass spectrometry (TI-IDMS), which was used as a reference method. Because of its high first ionization potential and its high volatility mercury could not be determined by TI-IDMS. A multi-element spike solution, containing isotopically enriched (206)pb, Cd-116, Cr-53, and Hg-201, was used for the Isotope dilution step. Decomposition of the polyolefin samples was carried out with concentrated HNO3 at temperatures of about 300 degrees C in a high pressure asher (HPA). This procedure decomposes polyolefins completely and allows isotopic equilibration between sample and spike isotopes. Detection limits of 16 ng/g, 5 ng/g, 164 ng/g, and 9 ng/g were obtained for Pb, Cd, Cr, and Hg by ICP-IDMS using only sample weights of 0.25 g. In different commercially available polyethylene samples heavy metal concentrations in the range of < 5 ng/g to 4 x 10(3) ng/g were analyzed. Both mass spectrometric methods were applied within the EU project ''Polymeric Elemental Reference Material (PERM)" for the certification of two polyethylene reference materials. The ICP-IDMS results agreed very well with those of TI-IDMS which demonstrates the accuracy of the ICP-IDMS method also suitable for routine analyses.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 12 条
[1]  
Bohm L, 1998, KUNSTST-PLAST EUR, V88, P1864
[2]  
DEBIEVRE P, 1990, FRESEN J ANAL CHEM, V337, P776
[3]   DETERMINATION OF TRACE-ELEMENTS IN FOOD CONTACT POLYMERS BY SEMIQUANTITATIVE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - PERFORMANCE EVALUATION USING ALTERNATIVE MULTIELEMENT TECHNIQUES AND IN-HOUSE POLYMER REFERENCE MATERIALS [J].
FORDHAM, PJ ;
GRAMSHAW, JW ;
CASTLE, L ;
CREWS, HM ;
THOMPSON, D ;
PARRY, SJ ;
MCCURDY, ED .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (04) :303-309
[4]   ELEMENT RESIDUES IN FOOD CONTACT PLASTICS AND THEIR MIGRATION INTO FOOD SIMULANTS, MEASURED BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
FORDHAM, PJ ;
GRAMSHAW, JW ;
CREWS, HM ;
CASTLE, L .
FOOD ADDITIVES AND CONTAMINANTS, 1995, 12 (05) :651-669
[5]   CBNM CERTIFICATION OF CD IN POLYETHYLENE BY ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
GOTZ, A ;
LAMBERTY, A ;
DEBIEVRE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (01) :1-6
[6]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[7]  
HEUMANN KG, 1985, INORGANIC MASS SPECT, P301
[8]   STORAGE AND STABILITY OF INORGANIC AND METHYLMERCURY SOLUTIONS [J].
LEERMAKERS, M ;
LANSENS, P ;
BAEYENS, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (08) :655-662
[9]   NEUTRON-ACTIVATION ANALYSIS FOR THE DETERMINATION OF CONTAMINANTS IN FOOD CONTACT MATERIALS [J].
THOMPSON, D ;
PARRY, SJ ;
BENZING, R .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 195 (01) :209-217
[10]  
Van Borm W, 1999, FRESEN J ANAL CHEM, V365, P361