Evaluation of 3-D colour Doppler ultrasound for the measurement of proximal isovelocity surface area

被引:15
作者
DeGroot, C
Drangova, M
Fenster, A
Zhu, SP
Pflugfelder, PW
Boughner, DR
机构
[1] John P Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] London Hlth Sci Ctr, London, ON, Canada
基金
英国医学研究理事会;
关键词
three-dimensional ultrasound; proximal iso velocity surface area; colour Doppler; flow convergence; valvular regurgitation; PISA; 3-D;
D O I
10.1016/S0301-5629(00)00245-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) colour Doppler ultrasound (US) enables flow rate estimation across a diseased valve without the need for a priori geometric assumptions. This study quantitatively evaluates the accuracy of 3-D colour Doppler US for measuring the flow rate (8.3-75 mL/s) through a valve using the proximal how convergence field, Flow rate measurements by this 3-D technique underestimate how through finite circular orifices due to two major sources of error: 1. surface area slicing technique (18.3% +/- 3.8%) and 2. Doppler angle effect(41.0% +/- 1.5%). Combined total underestimation is 51% +/- 3.3%. To utilize 3-D US, the development of an improved proximal isovelocity surface area (PISA) measurement technique and a correction factor for the Doppler angle effect is required. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:989 / 999
页数:11
相关论文
共 43 条
[1]   Quantitative assessment of chronic aortic regurgitation with 3-dimensional echocardiographic reconstruction: Comparison with electromagnetic flowmeter measurements [J].
Acar, P ;
Jones, M ;
Shiota, T ;
Masani, N ;
Delabays, A ;
Yamada, I ;
Sahn, DJ ;
Pandian, NG .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) :138-148
[2]   A NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE FLOW ACCELERATION REGION PROXIMAL TO AN ORIFICE [J].
ANAYIOTOS, AS ;
PERRY, GJ ;
MYERS, JG ;
GREEN, DW ;
FAN, PH ;
NANDA, NC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04) :501-516
[3]   An improved flow evaluation scheme in orifices of different aspect ratios [J].
Anayiotos, AS ;
Elmahdi, AM ;
Newman, BE ;
Perry, GJ ;
Costa, F ;
Agrawal, D ;
Agrawal, G ;
DeCarvalho, CT ;
Nanda, NC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :231-244
[4]  
Barclay S A, 1993, J Am Soc Echocardiogr, V6, P433
[5]   A NEW METHOD FOR QUANTITATION OF MITRAL REGURGITATION BASED ON COLOR FLOW DOPPLER IMAGING OF FLOW CONVERGENCE PROXIMAL TO REGURGITANT ORIFICE [J].
BARGIGGIA, GS ;
TRONCONI, L ;
SAHN, DJ ;
RECUSANI, F ;
RAISARO, A ;
DESERVI, S ;
VALDESCRUZ, LM ;
MONTEMARTINI, C .
CIRCULATION, 1991, 84 (04) :1481-1489
[6]   IMPACT OF IMPINGING WALL JET ON COLOR DOPPLER QUANTIFICATION OF MITRAL REGURGITATION [J].
CHEN, CG ;
THOMAS, JD ;
ANCONINA, J ;
HARRIGAN, P ;
MUELLER, L ;
PICARD, MH ;
LEVINE, RA ;
WEYMAN, AE .
CIRCULATION, 1991, 84 (02) :712-720
[7]   Three-dimensional color Doppler: A clinical study in patients with mitral regurgitation [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Albers, J ;
Meinzer, HP ;
Hagl, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1646-1654
[8]   Three-dimensional Doppler - Techniques and clinical applications [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Meinzer, HP ;
Hagl, S .
EUROPEAN HEART JOURNAL, 1999, 20 (08) :619-627
[9]   EFFECTIVE MITRAL REGURGITANT ORIFICE AREA - CLINICAL USE AND PITFALLS OF THE PROXIMAL ISOVELOCITY SURFACE-AREA METHOD [J].
ENRIQUEZSARANO, M ;
MILLER, FA ;
HAYES, SN ;
BAILEY, KR ;
TAJIK, AJ ;
SEWARD, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) :703-709
[10]   COLOR FLOW IMAGING COMPARED WITH QUANTITATIVE DOPPLER ASSESSMENT OF SEVERITY OF MITRAL REGURGITATION - INFLUENCE OF ECCENTRICITY OF JET AND MECHANISM OF REGURGITATION [J].
ENRIQUEZSARANO, M ;
TAJIK, AJ ;
BAILEY, KR ;
SEWARD, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) :1211-1219