Physical basis of pressure transfer from periphery to aorta: a model-based study

被引:59
作者
Stergiopulos, N [1 ]
Westerhof, BE
Westerof, N
机构
[1] Swiss Fed Inst Technol, PSE Ecublens, Biomed Engn Lab, CH-1015 Lausanne, Switzerland
[2] Univ Amsterdam, Acad Med Ctr, Netherlands Org Appl Sci Res, Inst Appl Phys,Biomed Instrumentat Dept, NL-1105 AZ Amsterdam, Netherlands
[3] Free Univ Amsterdam, Inst Cardiovasc Res, Physiol Lab, NL-1081 BT Amsterdam, Netherlands
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 04期
关键词
forward and backward waves; wave propagation; reflection coefficient; carotid and brachial arteries;
D O I
10.1152/ajpheart.1998.274.4.H1386
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We propose a new method to derive aortic pressure from peripheral pressure and velocity by using a time domain approach. Peripheral pressure is separated into its forward and backward components, and these components are then shifted with a delay time, which is the ratio of wave speed and distance, and added again to reconstruct aortic pressure. We tested the method on a distributed model of the human systemic arterial tree. From carotid and brachial artery pressure and velocity, aortic systolic and diastolic pressure could be predicted within 0.3 and 0.1 mmHg and 0.4 and 1.0 mmHg, respectively. The central aortic pressure wave shape was also predicted accurately from carotid and brachial pressure and velocity (root mean square error: 1.07 and 1.56 mmHg, respectively). The pressure transfer function depends on the reflection coefficient at the site of peripheral measurement and the delay time. A 50% decrease in arterial compliance had a considerable effect on reconstructed pressure when the control transfer function was used. A 70% decrease in arm resistance did not affect the reconstructed pressure. The transfer function thus depends on wave speed but has Little dependence on vasoactive state. We conclude that central aortic pressure and the transfer function can be derived from peripheral pressure and velocity.
引用
收藏
页码:H1386 / H1392
页数:7
相关论文
共 21 条
[1]   THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE [J].
BOS, WJW ;
IMHOLZ, BPM ;
VANGOUDOEVER, J ;
WESSELING, KH ;
VANMONTFRANS, GA .
AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) :529-535
[2]   Reconstruction of brachial artery pressure from noninvasive finger pressure measurements [J].
Bos, WJW ;
vanGoudoever, J ;
vanMontfrans, GA ;
vandenMeiracker, AH ;
Wesseling, KH .
CIRCULATION, 1996, 94 (08) :1870-1875
[3]   Validation of carotid artery tonometry as a means of estimating augmentation index of ascending aortic pressure [J].
Chen, CH ;
Ting, CT ;
Nussbacher, A ;
Nevo, E ;
Kass, DA ;
Pak, P ;
Wang, SP ;
Chang, MS ;
Yin, FCP .
HYPERTENSION, 1996, 27 (02) :168-175
[4]  
Chen CH, 1997, CIRCULATION, V95, P1827
[5]   Models of brachial to finger pulse wave distortion and pressure decrement [J].
Gizdulich, P ;
Prentza, A ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1997, 33 (03) :698-705
[6]   AN ANALYSIS OF THE RELATIONSHIP BETWEEN CENTRAL AORTIC AND PERIPHERAL UPPER LIMB PRESSURE WAVES IN MAN [J].
KARAMANOGLU, M ;
OROURKE, MF ;
AVOLIO, AP ;
KELLY, RP .
EUROPEAN HEART JOURNAL, 1993, 14 (02) :160-167
[7]   PRESSURE WAVE-PROPAGATION IN A MULTIBRANCHED MODEL OF THE HUMAN UPPER-LIMB [J].
KARAMANOGLU, M ;
GALLAGHER, DE ;
AVOLIO, AP ;
OROURKE, MF .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04) :H1363-H1369
[8]   THE STATIC ELASTIC PROPERTIES OF 45 HUMAN THORACIC AND 20 ABDOMINAL AORTAS INVITRO AND THE PARAMETERS OF A NEW MODEL [J].
LANGEWOUTERS, GJ ;
WESSELING, KH ;
GOEDHARD, WJA .
JOURNAL OF BIOMECHANICS, 1984, 17 (06) :425-435
[10]   WAVE REFLECTIONS AND CARDIAC-HYPERTROPHY IN CHRONIC UREMIA - INFLUENCE OF BODY-SIZE [J].
MARCHAIS, SJ ;
GUERIN, AP ;
PANNIER, BM ;
LEVY, BI ;
SAFAR, ME ;
LONDON, GM .
HYPERTENSION, 1993, 22 (06) :876-883