Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve

被引:128
作者
Lago, N
Ceballos, D
Rodríguez, FJ
Stieglitz, T
Navarro, X
机构
[1] Autonomous Univ Barcelona, Inst Neurosci, Dept Cell Biol Physiol & Immunol, E-08193 Bellaterra, Spain
[2] Fraunhofer Inst Biomed Engn, Neural Prosthet Unit, St Ingbert, Germany
关键词
interface; motor axons; nerve regeneration; neural prosthesis; peripheral nerve; polyimide; regenerative electrode;
D O I
10.1016/j.biomaterials.2004.06.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyimide sieve electrodes were implanted between the severed ends of the sciatic nerve in rats. The degree of axonal regeneration through the electrode was examined by physiological and histological methods from 2 to 12 months post implantation. Regeneration was successful in the 30 animals implanted. Functional reinnervation of hindlimb targets progressed to reach maximal levels at 6 months. Comparatively, the reinnervation of distal plantar muscles was lower than that of proximal muscles and of digital nerves. The number of regenerated myelinated fibers increased from 2 to 6 months. when it was similar to control values. The Majority of myelinated fibers crossing the via holes and regenerated through the distal nerve had a normal appearance. However. in a few cases decline of target reinnervation and loss of regenerated nerve fibers was found from 6 to 12 months postimplantation. Motor axons labeled by ChAT immunoreactivity regenerated scattered within minifascicles, although they were found at higher density at the periphery of the regenerated nerve. The number of ChAT-positive axons was markedly lower distally than proximally to the sieve electrode. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2021 / 2031
页数:11
相关论文
共 40 条
[1]  
AVENDANO C, 2003, SOC NEUROSCI
[2]   Glial cell line-derived neurotrophic factor and brain-derived neurotrophic factor sustain the axonal regeneration of chronically axotomized motoneurons in vivo [J].
Boyd, JG ;
Gordon, T .
EXPERIMENTAL NEUROLOGY, 2003, 183 (02) :610-619
[3]   Long term chronic recordings from peripheral sensory fibers using a sieve electrode array [J].
Bradley, RM ;
Cao, XG ;
Akin, T ;
Najafi, K .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 73 (02) :177-186
[4]   A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats [J].
Branner, A ;
Normann, RA .
BRAIN RESEARCH BULLETIN, 2000, 51 (04) :293-306
[5]   Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes [J].
Branner, A ;
Stein, RB ;
Normann, RA .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 85 (04) :1585-1594
[6]   Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long-term implantation [J].
Ceballos, D ;
Valero-Cabré, A ;
Valderrama, E ;
Schüttler, M ;
Stieglitz, T ;
Navarro, X .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 60 (04) :517-528
[7]   Multi-unit recording from regenerated bullfrog eighth nerve using implantable silicon-substrate microelectrodes [J].
DellaSantina, CC ;
Kovacs, GTA ;
Lewis, ER .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 72 (01) :71-86
[8]   A PERIPHERAL-NERVE INFORMATION TRANSDUCER FOR AMPUTEES - LONG-TERM MULTICHANNEL RECORDINGS FROM RABBIT PERIPHERAL-NERVES [J].
EDELL, DJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :203-214
[9]   Peripheral afferents with common function cluster in the median nerve and somatotopically innervate the human palm [J].
Ekedahl, R ;
Frank, O ;
Hallin, RG .
BRAIN RESEARCH BULLETIN, 1997, 42 (05) :367-376
[10]   A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues [J].
Gonzalez, C ;
Rodriguez, M .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 72 (02) :189-195