Comparison of three small chamber test methods for the measurement of VOC emission rates from paint

被引:54
作者
Afshari, A
Lundgren, B
Ekberg, LE
机构
[1] Aalborg Univ, Danish Bldg & Urban Res, Energy & Indoor Climate Div, DK-2970 Horsholm, Denmark
[2] Chalmers, Dept Bldg Serv, S-41296 Gothenburg, Sweden
[3] SP Swedish, Natl Testing & Res Inst, Boras, Sweden
关键词
CLIMPAQ; 1-m(3) chamber; FLEC; VOC; emission rate; concentration; paint;
D O I
10.1034/j.1600-0668.2003.00146.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this study was to demonstrate a correlation between the measurement of emission rates of volatile organic compounds (VOCs) in three different climate chambers. In order to achieve this aim, the early state of the emission process in the three chambers was investigated and the effects of some important factors on the emission rates from paint were determined. The paper presents results of measurements in three different climate chambers. For the study, a 1-m(3) chamber, a field and laboratory emission cell (FLEC), and a chamber for laboratory investigation of materials pollution and air quality (CLIMPAQ) were used. The airflow and surface area were selected so that the area-specific ventilation rates were identical in the three chambers. Temperature and relative humidity were identical during all the measurements. The paint examined was a solvent-based alkyd paint intended for indoor, which use contained between 30 and 60% of white spirit in wet condition. The paint was applied to electropolished and cleaned stainless steel plates. After application, the test material was stored for 14 days for drying in a well-ventilated conditioning room before the measurements were made. After 2 weeks storage, the most pronounced emissions were pentanal, hexanal, octanal, and decanol. The period before the emission rate stabilized differed for the three chambers studied. However, all chambers gave similar emission rates within the overall uncertainty used in these experiments.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 18 条
[1]  
AFSHARI A, 1995, P INT C VOL ORG COMP, P99
[2]  
AFSHARI A, 1996, DETERMINATION VOC EM
[3]  
[Anonymous], 1994, 1297 NIST US DEP COM
[4]  
[Anonymous], 1993, GUID EXPR UNC MEAS
[5]  
*ASTM, 1992, D511690 ASTM
[6]  
*CEC, 1992, 13593 EUR EN CEC
[7]  
*CEN, 1998, 13419 ENV CEN EUR CO
[8]   COMPENSATING FOR SINK EFFECTS IN EMISSIONS TEST CHAMBERS BY MATHEMATICAL-MODELING [J].
DUNN, JE ;
TICHENOR, BA .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (05) :885-894
[9]  
*EES, 1992, ENG EQ SOLV F CHART
[10]   The influence of area-specific ventilation rate on the emissions from construction products [J].
Gunnarsen, L .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1997, 7 (02) :116-120