Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on a carbon ionic liquid electrode modified with mesoporous molecular sieve MCM-41

被引:25
作者
Li, Yonghong [1 ]
Zeng, Xiandong [1 ]
Liu, Xiaoying [1 ]
Liu, Xinsheng [2 ]
Wei, Wanzhi [1 ]
Luo, Shenglian [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Nonferrous Fluoride Chem Co Ltd, Xiangxiang 411400, Hunan, Peoples R China
基金
美国国家科学基金会;
关键词
Hemoglobin; MCM-41; Carbon ionic liquid electrode; Direct electrochemistry; Hydrogen peroxide; BY-LAYER FILMS; PASTE ELECTRODE; CHITOSAN; SILICA; SILVER;
D O I
10.1016/j.colsurfb.2010.04.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The direct electron transfer and electrocatalysis of hemoglobin (Hb) entrapped in the MCM-41 modified carbon ionic liquid electrode (CILE) were investigated by using cyclic voltammetry in 0.10 M pH 7.0 phosphate buffer solution (PBS). Due to its uniform pore structure, high surface areas and good bio-compatibility, the mesoporous silica sieve MCM-41 provided a suitable matrix for immobilization of biomolecule. The MCM-41 modified CILE showed significant promotion to the direct electron transfer of Hb, which exhibited a pair of well defined and quasi-reversible peaks for heme Fe(III)/Fe(II) with a formal potential of -0.284V (vs. Ag/AgCl). Additionally, the Hb immobilized on the MCM-41 modified carbon ionic liquid electrode showed excellent electrocatalytic activity toward H2O2. The electrocatalytic current values were linear with increasing concentration of H2O2 in a wide range of 5-310 mu M and the corresponding detection limit was calculated to be 5 x 10(-8) M (S/N = 3). The surface coverage of Hb immobilized on the MCM-41 modified carbon ionic liquid electrode was about 2.54 x 10(-9) mol cm(-2). The Michaelis-Menten constant K-m(app) of 214 mu M indicated that the Hb immobilized on the modified electrode showed high affinity to H2O2. The proposed electrode had high stability and good reproducibility clue to the protection effect of MCM-41 and ionic liquid, and it would have wide potential applications in direct electrochemistry, biosensors and biocatalysis. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 35 条
[1]   A KINETIC-STUDY ON THE SUICIDE INACTIVATION OF PEROXIDASE BY HYDROGEN-PEROXIDE [J].
ARNAO, MB ;
ACOSTA, M ;
DELRIO, JA ;
VARON, R ;
GARCIACANOVAS, F .
BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1041 (01) :43-47
[2]  
BARD AJ, 1986, ELECTROANALYTICAL CH, V13, P191
[3]   Use of room temperature ionic liquids in gas sensor design [J].
Buzzeo, MC ;
Hardacre, C ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4583-4588
[4]   Direct electron transfer and enzymatic activity of hemoglobin in a hexagonal mesoporous silica matrix [J].
Dai, ZH ;
Liu, SQ ;
Ju, HX ;
Chen, HY .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :861-867
[5]   Direct electron transfer and electrocatalysis of hemoglobin adsorbed onto electrodeposited mesoporous tungsten oxide [J].
Feng, JJ ;
Xu, JJ ;
Chen, HY .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (01) :77-82
[6]   DDirect electrochemistry of heme multicofactor-containing enzymes on alkanethiol-modified gold electrodes [J].
Ferapontova, EE ;
Gorton, L .
BIOELECTROCHEMISTRY, 2005, 66 (1-2) :55-63
[7]   Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors [J].
Gorton, L ;
Lindgren, A ;
Larsson, T ;
Munteanu, FD ;
Ruzgas, T ;
Gazaryan, I .
ANALYTICA CHIMICA ACTA, 1999, 400 :91-108
[8]   MCM-41 mesoporous material modified carbon paste electrode for the determination of cardiac troponin I by anodic stripping voltammetry [J].
Guo, HS ;
He, NY ;
Ge, SX ;
Yang, D ;
Zhang, JN .
TALANTA, 2005, 68 (01) :61-66
[9]   Electrochemical deposition of silver in room-temperature ionic liquids and its surface-enhanced Raman scattering effect [J].
He, P ;
Liu, HT ;
Li, ZY ;
Liu, Y ;
Xu, XD ;
Li, JH .
LANGMUIR, 2004, 20 (23) :10260-10267
[10]   Assembly of electroactive layer-by-layer films of hemoglobin and polycationic poly(diallyldimethylammonium) [J].
He, PL ;
Hu, NF ;
Zhou, G .
BIOMACROMOLECULES, 2002, 3 (01) :139-146